I Setting the Fan Speed
• Press 4 to select:-
FAN
– Low Fan Speed
FAN
– Medium Fan Speed
FAN
– High Fan Speed
AUTO
FAN
Automatic Fan Speed
The speed of the indoor fan is adjusted
automatically according to the operation.
The indoor fan stops occasionally during
cooling operation.
I Setting the Vertical Airflow Direction
• Press 5 or 6 to select:-
Cooling Model
COOL / DRY Operation
AUTO
36°
Swing up/down
Automatically
MANUAL
Five stages of adjustment
can be made between
14° ~ 36°.
Heat Pump Model
COOL / DRY Operation
AUTO
36°
Swing up/down
Automatically
MANUAL
Five stages of adjustment
can be made between
14° ~ 36°.
AUTOHEAT
COOL
AUTO
AUTO
FAN
8
MODE
QUIET
7
AIR SWING
AUTO
MANUAL
1
2
1
ON
5
OFF
TIMER
CHECK
RESET CLOCK
SETTING THE TIMER
Ensure that the current time is correct before setting the
timer. The timer cannot be set if the time display is
flashing.
I ON-TIMER Operation
To start the air conditioner operation automatically.
• Press 1 to set the operation.
• Press 2 to increase or decrease the time.
• Then press 3.
• To cancel this operation, press 4.
I OFF-TIMER Operation
To stop the air conditioner operation automatically.
• Press 5 to set the operation.
• Press 2 to increase or decrease the time.
• Then press 3.
• To cancel this operation, press 4.
G Timer Mode Operation Details
• When the ON-Timer is set, operation will start
before the actual set time. This is to enable the
room temperature reaches the set temperature at
the set time.
Cooling Model
COOL,DRY, –>15 minutes
AUTO
in advance
• Once the ON/OFF Timer is set, operation will start/
stop at the set time everyday.
• The current time is not displayed when the timers
are set.
• When both timers are used together, the TIMER
mode indicator on the indoor unit remains lit even
when the operation is stopped by the OFF-TIMER.
I Setting the Horizontal Airflow Direction
• Adjust it manually
G Use this air conditioner under the following
conditions:
FAN Operation
AUTO
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
Maximum Temperature
61°
Minimum Temperature
Move up/down
Automatically
MANUAL
Five stages of adjustment
can be made between
0° ~ 61°.
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
Maximum Temperature-Cooling
(Maximum Temperature-Heating)
HEAT Operation
AUTO
Minimum Temperature-Cooling
(Minimum Temperature-Heating)
– When the discharge air
temperature is low such
as at the start of heating
G Notes
operation, the air blows
at horizontal level. As
If the unit is not going to be used for an extended
the temperature rises,
period of time, turn off the main power supply. If it is
the hot air blows at a
left at the ON position, approximately 2.5 W of
downward direction.
electricity will be used even if the indoor unit has been
– To stop this operation,
turned off with the remote control.
press MANUAL.
If operation is stopped, then restart immediately, the
MANUAL
unit will resume operation only after 3 minutes.
Five stages of adjustment
can be made between
0° ~ 61°.
DRY FAN

CONVENIENCE OPERATION

OFF/ON
I Powerful Mode Operation
To obtain the set temperature quickly.
• Press 6.
POWERFUL
6
* Powerful mode indicator (orange) on the indoor
unit will light up.
FAN SPEED
* Powerful mode will operate for 15 minutes only.
3
3
• To cancel this operation, press once more.
SET
4
G Powerful Mode Operation Details
CANCEL
2
• The changes of the temperature and airflow volume
are automatic.
• The remote control display remains unchanged.
• If operation mode button is pressed, powerful
operation will be cancelled.
• During FAN – Air circulation operation, the powerful
operation are not available.
(cooling model only)
Powerful Mode
Operation
COOL / DRY
HEAT
(for Heat Pump
model only)
Heat Pump Model
COOL,DRY, –>15 minutes
in advance
HEAT, AUTO –>30 minutes
in advance
www.ilmalämpöpumput.com
CS-W7CKP CU-W7CKP5 / CS-W9CKP CU-W9CKP5 / CS-W12CKP CU-W12CKP5
G Operation Details
COOL – Cooling Operation
To set the room temperature at your preference
cooling comfort.
AUTO – Automatic Operation
Sense indoor temperature to select the optimum
mode.
Temperature is not displayed on the remote control
during AUTO operation.
DRY – Soft Dry Operation
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
Cooling Model
temperature.
During Soft Dry operation, the indoor fan operates at
Unit in °C
Low fan speed.
Indoor
Outdoor
DBT
WBT
DBT
WBT
HEAT – Heating Operation
(for Heat Pump Model only)
32
23
26
43
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
16
11
11
16
falls, the heating capacity of the unit might be
reduced.
Defrosting Operation
Heat Pump Model
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
Unit in °C
unit.
Indoor
Outdoor
FAN – Air Circulation Operation
DBT
WBT
DBT
WBT
(for Cooling Model only)
32
23
43
26
When the room temperature reaches the set
(30)
(-)
(24)
(18)
temperature, operation commences at Low airflow
volume. It stops when the room temperature drops to
16
11
16
11
2°C below the set temperature.
(16)
(-)
(-5)
(-6)
(It is useful when using a heater).
I Quiet Mode Operation
To provide quiet operation.
• Press 7.
* Quiet mode indicator on the indoor unit will light
• To cancel this operation, press once more.
G Operation Details
• Air flow sound will reduce during operation.
I Ionizer Mode Operation
Produce negative ion for fresh air.
• Press 8.
* Ion mode indicator on the indoor unit will light up.
• To cancel this operation, press once more.
G Operation Details
• Air conditioner ON:
• Air conditioner OFF:
Temperature
Airflow
• If blinking, press 8 twice.
volume
3°C lower
than set temp.
Super High
3°C higher
than set temp.
Automatic
41
up.
Provide negative ion during operation.
Provide negative ion with FAN operation.
If still blinking, please call service.