Keypad Installation

For best viewing and usage, the MDK-C6 should be
mounted at thermostat height, or about 58"-60" (1.5m) from
the fl oor.
To install a double-gang keypad, you will need a UL/CSA
approved plastic 32ci double-gang wall box. Attach the box
to the wall with appropriate fasteners.
For installations employing a retrofi t box or P-ring, the two
foam spacers on the rear of the keypad's metal back plate
can be removed for a better fi t.
Route CAT-5e cable to the wall box from the controller.
There should be not more than 250 feet of CAT-5e cable
between the keypad and the controller.
Terminate the CAT-5e cable with an RJ-45 connector, using
the T568A wiring standard. Insert the RJ-45 connector into
the jack marked "Controller" on the back of the keypad.
Mount the keypad in the wall box and attach the cover
plate. Repeat the steps until all keypads are installed.
Double-gang wall box
MDK-C6 keypad
Russound MDK-C6 User and Installation Manual
KEYPAD INSTALLATION
CAUTION
Mounting screws must be hand-
tightened. Over-tightening the
mounting screws can cause the
buttons to jam and malfunction.
Cover plate