Download Print this page

KING KBP2406 Installaltion & Maintenance Manual page 2

240v-1phase unit heater

Advertisement

King electrical mfg. company
Wiring Heater
WARNING - Before proceeding further with
the installation of this heater, turn off the
power and lock the supply line for the heater
at the main service box.
Remove wiring compartment cover.
1)
2)
Remove one of the knock outs from back of unit. It
is not necessary to remove grill covers.
Size service wire to adequately handle amp load of
3)
heater. Refer to the Circuit Sizing Table for proper
wire size and circuit protection.
Connect supply wire to L1 & L2 as shown in the
4)
diagram below.
Secure power supply cable with clamps.
5)
Connect ground wire to the green pig tail.
6)
7)
Reinstall wiring compartment cover.
Adjust the heater to the desired position.
8)
INSTALLATION INSTRUCTIONS
This heater is shipped from the factory wired for
maximum wattage of 5700 Watts at 240 Volts. To
reduce the wattage unplug (disconnect) an insulated
push on terminal and wrap with electrical tape to
prevent the possibility of electrical contact with other
parts.
Feild Wattage Selection
1. 5700 Watts factory wired
2. 4750 Watts disconnect terminal A
3. 3800 Watts disconnect terminals A,D
4. 2850 Watts disconnect terminals A,B,D
5. 1900 Watts disconnect terminals A,B,C,D
E - Black
Do Not Disconnect (Common)
F - Red
Do Not Disconnect
E Common
A
F
950
950
E Common
C
F
950
950
END VIEW OF ELEMENT
SHOWING QUICK CONNECT TERMINALS
1900•2850•3800•4750•5700
WATTAGES AVAILABLE IN ONE UNIT
Maintenance & Warranty Information:
The high quality and superior design of the Pic-a-Watt heater will provide years of trouble free performance.
Each year the heater should be checked and cleaned for lint and dust accumulation. We recommend using a
soft bristled brush such as a paint brush to assist in removing contaminants from the heater. The motor is
permanently lubricated and does not need servicing. King Mfg. Co. will repair or replace, without charge any
KBP2406 heater found to be defective or malfunctioning for five years after purchase to the original owner.
9131 - 10th Avenue South Seattle Washington 98108
*Per the National Electric Code heating circuits are considered a continuos load
and therfore must be derated by 20%. For example a 20 amp heating circuit
cannot have more than 16 amps of load connected. If heater is operated at
208V it will draw 13% less amps and produce 25% less wattage.
A
ORANGE
F
RED
B
BLUE
Insulated Push on
Terminal
C
YELLOW
F
RED
D
GRAY
Insulated Push on
Terminal
BLACK #14
Thermostat
B
RED #14
950
OFF ....... L1-0, L2-0
FAN ....... L1-2, L2-4
HEAT...... L1-1, L2-4, L2-3
D
FAN DELAY
1-3 N.C., 1-2 N.O.
950
1-2 Closes on Temp Rise
Pic-A-Watt
Metal Sheath Element
CIRCUIT SIZING TABLE
Watts
BTUH
Volts
1,900
6,484
240
2,850
9,727
240
3,800
12,969
240
4,750
16,211
240
5,700
19,454
240
950 WATT
950 WATT
950 WATT
950 WATT
950 WATT
950 WATT
FAN
DELAY
2
1
BLACK#16
FAN
3
PURPLE #16
GRAY #16
1
Rotory Switch
KBP2406
240V -1ph
Amps
Wire
Circuit*
1-Phase
Size
Protection
8
#14/2
15A-2P
12
#14/2
15A-2P
16
#12/2
20A-2P
20
#10/2
30A-2P
24
#10/2
30A-2P
E
E
LIMIT
BLACK #16
ORANGE #14
3
4
2
A
B
L1
L2
kbp2406.pm65 rev 02/03

Advertisement