Sony CDP-CX333ES Service Manual page 20

Hide thumbs Also See for CDP-CX333ES:
Table of Contents

Advertisement

Disc In Detect Sensor Adjustment
Be sure to perform this adjustment after sensor adjustment in
MECHANICAL ADJUSTMENT.
Connection:
MAIN board
CN506
T.P: Pin 1
T.P
D.S: Pin 3
GND
GND: Pin 2
D.S
Waveform:
1. Connect the oscilloscope to Pins 1, 2, and 3 of CN506 of
the MAIN board.
2. Check that no discs are loaded in the unit.
3. With the power ON, while pressing the
[   OPEN/CLOSE]
buttons, press the
§
table starts to rotate in the clockwise direction.
4. Loosen the fixing screw, move the mounting board (SENSOR),
and secure the mounting board (SENSOR) at the point the H
portion of the P.T waveform comes the center of the H portion
of the D.S waveform.
Fixing screw
Mounting board (SENSOR)
20
oscilloscope
D.S
P.T
[GROUP 5]
and
[+100]
button. The disc
D.S
P.T
Should be at the center
[DISC/CHARACTER]
5. Rotate the
wise direction and the disc table starts to rotate in the same
direction. Check that the waveform at this time is the same as
that in step 4. If larger by a considerable extent, rotate the
[DISC/CHARACTER]
knob in the clockwise direction and the
disc table starts to rotate in the same direction. Repeat from
step 4.
6. Rotate RV501 of the MAIN board and adjust so that the H and
L portions of the D.S waveform become the same.
Adjust so that these widths
become the same.
Adjustment Location: MAIN board
• Adjustment Location
– BD BOARD (Conductor Side) –
TP
(RFO)
TP
(FE1)
TP
(TE)
IC103
TP
(VC)
– MAIN BOARD (Component Side) –
CN506
1
RV501
knob in the counterclock-
D.S
IC101
3