Cd Section - Sony HCD-MG110 Service Manual

Hide thumbs Also See for HCD-MG110:
Table of Contents

Advertisement

HCD-MG110/MG310AV
Ver 1.1

CD SECTION

Note:
1. CD Block is basically designed to operate without adjustment. There-
fore, check each item in order given.
2. Use PATD-012 disc (4-225-203-01) unless otherwise indicated.
3. Use an oscilloscope with more than 10MW impedance.
4. Clean the object lens by an applicator with neutral detergent when the
signal level is low than specified value with the following checks.
S Curve Check
Connection:
CD board
TP (FE)
TP (VC)
Procedure:
1.
Connect an oscilloscope to test point TP (FEI) and TP (VC) on
the CD board.
2.
Turn the power on.
3.
Put the disc (PATD-012) in and turned power switch on again
and actuate the focus search. (actuate the focus search when
disc table is moving in and out)
4.
Check the oscilloscope waveform (S-curve) is symmetrical
between A and B. And confirm peak to peak level within 2 ± 1
Vp-p.
S-curve waveform
Note: • Try to measure several times to make sure than the ratio of A : B
or B : A is more than 10 : 7.
• Take sweep time as long as possible and light up the
brightness to obtain best waveform.
Checking Location: CD board
RFDC Level Check
Connection:
CD board
TP (RFDC)
TP (VC)
Procedure:
1.
Connect an oscilloscope to test point TP (RFDC) and TP (VC)
on the CD board.
2.
Turn the power on.
3.
Put the disc (PATD-012) in to playback the number two track.
4.
Confirm that oscilloscope waveform is clear and check RFDC
signal level is correct or not.
Note: A clear RFDC signal waveform means that the shape "◊" can be
clearly distinguished at the center of the waveform.
18
oscilloscope
+
symmetry
A
within 2 ± 1 Vp-p
B
oscilloscope
+
RFDC signal waveform
Checking Location: CD board
RFAC Level Check
Connection:
CD board
TP (RFAC)
TP (VC)
Procedure:
1.
Connect an oscilloscope to test point TP (RFAC) and TP (VC)
on the CD board.
2.
Turn the power on.
3.
Put the disc (PATD-012) in to playback the number two track.
4.
Confirm that oscilloscope waveform is clear and check RFAC
signal level is correct or not.
Note: A clear RFAC signal waveform means that the shape "◊" can be
clearly distinguished at the center of the waveform.
RFAC signal waveform
Checking Location: CD board
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level: 1.15 ± 0.35 Vp-p
oscilloscope
+
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level: 1.35 ± 0.4 Vp-p