Removal Procedure of Outdoor Unit

Be sure to wait for a minimum of 10 minutes after turning off all power supplies before disassembly.
STEPS
1. Remove top cover and front side plate
2. Remove grille
3. Remove panel
Johnson Controls Unitary Products
a. Use the screwdriver to remove
the screws connecting the top
panel and panel and side panels.
Remove the top panel. Loosen the
screws fixing the valve cover and
then remove the valve cover.
b. Loosen the screws connecting the front
side panel and mask and chassis.
Remove the front side panel.
Twist off the screws connecting the grille
and panel, and then remove the grille.
Twist off the screws connecting the panel,
chassis and motor support with screwd-river,
and then remove the panel.
PROCEDURES
Front Side Plate
Grille
Panel
923178-UTG-B-0114
Top Panel
Valve Cover