Sharp AF-S60FX Service Manual page 7

Room air conditioner
Table of Contents

Advertisement

5. AF-R100FX
Cooling Capacity
Moisture Removal
Electrical Data
Phase
Rared frequency
Rated voltage
Rated current
Rated input
Power factor
EER
Compressor
Type
Model, Motor Output
REFRIGERANT SYSTEM
Evaporator
Condenser
Control O.D. x I.D x Length x Q'ty(mm) Capil-
lary Tube
Refrigerant Volume R-22 (OZ) Factory Charge
NET DIMENSIONS
Width Height Depth
Net Weight
GROSS DIMENSIONS
Width Height Depth
Gross Weight
FAN SYSTEM
Indoor side (Evaporator)
Outdoor side (Condenser)
Air Flow rate (Indoor side)
OTHERS
Safety devices
Air filter
Power cord length
Power plug type
BTU/h
10000
Pint/h
2.5
Single
Hz
60
Volts
115
Amps
9.3
Watts
1020
%
96
BTU/Wh
9.8
(Hermetically sealed rotary type)
44R241AG-FES, 950
Louver fin, Grooved tube, 7mm, hair pin
Louver fin, Grooved tube, 7mm, hair pin
2.5 x 1.3 x 1150 x 2
19.4
Inch (mm)
18.9" (480) x 14.4" (365) x 22.6" (575)
Lbs
72.7
Inch (mm)
22.1" (560) x 17.1" (435) x 24.6" (625)
Lbs
83.7
Centrifugal fan
Propeller fan
CFM
High / Med / Low
820/710/610
Compressor: Over load
Fan motor: Internal thermal protector
Polypropylene net
ft
6.0
125V, 15A
1 – 5
AFS120FX

Hide quick links: