Mobile Home Installation; Gas Installation; Optional Wall Switch Installation - Napoleon Vittoria GD19N Installation And Operation Instructions Manual

Table of Contents

Advertisement

MOBILE HOME INSTALLATION

This appliance is certifi ed to be installed as an OEM (Origi-
nal Equipment Manufacturer) installation in a manufactured
home or mobile home and must be installed in accordance
with the manufacturer's instructions and the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part
3280, in the United States or the Mobile Home Standard,
CAN/CSA Z240 MH Series, in Canada. This appliance is
only for use with the type(s) of gas indicated on the rating
plate. A conversion kit is supplied with the mobile home
appliance.
This Mobile/Manufactured Home Listed appliance comes fac-
tory equipped with a means to secure the unit. The fi replace
is equipped with two 1/4" diameter holes located in the front
left and right corners of the base. For mobile home installa-
tions, the fi replace must be fastened in place. Use #10 hex
head screws, inserted through the holes in the base to secure.
Always turn off the pilot and the fuel suuply at the source,
prior to moving the mobile home. After moving the mobile
home and prior to lighting the fi replace, ensure that the logs
are positioned correctly.
This appliance is certifi ed to be installed in an aftermarket
permanently located, manufactured (mobile) home, where
not prohibited by local codes.
This fi replace is only for use with the type of gas indicated
on the rating plate. This fi replace is not convertible for use
with other gases, unless a certifi ed kit is used.
Conversion Kits
The mobile home appliance is fi eld convertible between
Natural Gas (NG) and Propane (LP).
To convert from one gas to another consult your Napoleon
dealer/distributor.

GAS INSTALLATION

Proceed once the vent installation is complete.
NOTE: All gas connections must be contained within the
fi replace when complete.
1. Move the fi replace into position and secure to the fl oor
through the 1/4" holes located at either side of the base.
2. The fi replace is designed to accept 3/8" gas supply line.
The fi replace is equipped with a 3/8" manual shut-off valve.
3. Connect the gas supply in accordance to local codes.
In the absence thereof, install according to the National
Installation Code.
4. When fl exing any gas line, support the gas valve so that
the lines are not bent or kinked.
5. Check for gas leaks by brushing on a soap and water
solution.
DO NOT USE OPEN FLAME.
Purge all gas lines with the glass door of the stove re-
moved. Assure that a continuous gas fl ow is at the burner
before re-installing the door.
FIGURE 35
Manual Shut-off Valve
OPTIONAL WALL SWITCH
INSTALLATION
For ease of accessibility, an optional remote wall switch may
be installed in a convenient location. Route 2-strand (solid
core) millivolt wire through the electrical hole located at the
bottom left side of the unit. The recommended maximum lead
length depends on wire size:
WIRE SIZE
14 gauge
16 gauge
18 gauge
Do not connect either the wall switch, thermostat or gas
valve directly to 110 volt electricity.
®
19
Shown in
"OFF"
position.
MAX. LENGTH
100 feet
60 feet
40 feet
W415-0612 / A / 11.05.07