CONTROLLER
CONNECTOR
MANUAL
FREEWHEEL
LEVERS
REAR SECTION
FRONT SECTION
Figure 6. The Go-Chair Power Base
Electrical Components
The electrical components are located on the power base. The main circuit breaker is located on the front of the
battery box. The controller connector is located on the back of the power base. See figure 6.
Controller Connector: This is where the controller connects to the power base. Each controller uses a different
type of cable. Regardless of which type of controller is used, the cable must be secured to the assembly and not
allowed to drag on the floor.
Battery Box Charger Port: This enables you to charge the batteries either on the unit or when the battery box is
removed from the power base. See VI. "Batteries and Charging."
Main Circuit Breaker: The main circuit breaker is a safety feature built into your Go-Chair. When the batteries
and the motors are heavily strained (e.g., from excessive loads), the main circuit breaker trips to prevent damage
to the motors and the electronics. If the circuit trips, allow your Go-Chair to "rest" for approximately one minute.
Next, push in the circuit breaker button, turn on the controller, and continue normal operation. If the main circuit
breaker continues to trip repeatedly, contact an authorised Pride Provider.