3.0 INSTALLATION

WARNING: THE STREAMLINE IS AN OPEN OUTLET WATER HEATER. THE
OUTLET OF THE STREAMLINE ACTS AS A VENT AND MUST ONLY BE
CONNECTED TO HEATRAE SADIA VENTED TAPS. THESE FITTINGS MUST
NEVER BE BLOCKED, RESTRICTED OR MODIFIED, IN ANY WAY.
3.1 GENERAL
The Streamline must be vertically wall mounted using the wall bracket supplied.
The water inlet connection must always be at the top of the Streamline on the
right hand side.
3.2 LOCATION AND FIXING
1. Ensure that the wall can support the full weight of the Streamline (see p.4)
and that there are no hidden services (electricity, gas or water) below the
surface of the wall.
2. DO NOT install the Streamline where it may freeze.
3. Select a suitable location for the Streamline. Allow 100mm access above
and 50mm below for maintenance.
NOTE: National Wiring Rules may contain restrictions concerning the
installation of the Streamline in bathrooms.
The installation must be carried out in accordance with the relevant
requirements of:-
The appropriate Building Regulations, either the Building Regulations, the
Building Regulations (Scotland) or Building Regulations (Northern Ireland)
The Water Supply (Water Fitttings) Regulations in England & Wales or
Water Byelaws in Scotland
FIGURE 03 - FRONT COVER
6
COVER
SCREWS
HINGE AT
BOTTOM