Aiwa XR-MD510 Service Manual page 40

Md / cd stereo system
Hide thumbs Also See for XR-MD510:
Table of Contents

Advertisement

< DECK SECTION >
1. Tape Speed Adjustment
Settings : • Test tape : TTA–100
• Test point : TP8 (Lch), TP9 (Rch)
• Adjustment location : SFR1
Method : Play back (FWD) the test tape and adjust SFR1 so
that the frequency counter reads 3000Hz ± 5Hz and
± 45Hz (REV) with respect to forward speed.
2. Head Azimuth Adjustment
Settings : • Test tape : TTA–300
• Test point : TP8 (Lch), TP9 (Rch)
• Adjustment location : Head azimuth
Method : Play back (FWD) the 10kHz signal of the test tape
and adjust screw so that the output becomes
maximum. Next, perform on REV play mode.
3. PB Frequency Response Check
Settings : • Test tape : TTA–300
• Test point :TP8 (Lch), TP9 (Rch)
Method : Play back the 315Hz and 10kHz signals of the test
tape and check that the output ratio of the 10kHz
signal with respect to that of the 315Hz signal is
0dB ± 3dB.
4. PB Sensitivity Adjustment
Settings : • Test tape : TTA–200
• Test point : TP8 (Lch), TP9 (Rch)
• Adjustment location : SFR303 (Lch)
Method : Play back the test tape and adjust SFRs so that the
output level of the test points becomes 245mV ±
10mV.
5. REC/PB Frequency Response Adjustment
Settings : • Test tape : TTA–602
• Test point : TP8 (Lch), TP9 (Rch)
• Input signal : 1kHz / 10kHz (LINE IN)
• Adjustment location : SFR351 (Lch)
Method : Apply a 1kHz signal and REC mode. Then adjust
OSC attenuator so that the output level at the TP8,
TP9 becomes 0dB (17mV). Record and play back the
1kHz and 10kHz signals and adjust SFRs so that the
output of the 10kHz signals becomes 0dB ± 0.5dB
with respect to that of the 1kHz signal.
adjustment screw
SFR304 (Rch)
SFR352 (Rch)
6. REC/PB Sensitivity Adjustment
Settings : • Test tape : TTA–602
• Test point : TP8 (Lch), TP9 (Rch)
• Input signal : 1kHz (LINE IN)
• Adjustment location : SFR305 (Lch)
Method : Apply a 1kHz signal and REC mode. Then adjust
OSC attenuator so that the output level at TP8, TP9
becomes 0dB (170mV). Record and play back the
1kHz signals and adjust SFRs so that the output
becomes 0dB ± 0.5dB.
< FRONT SECTION >
7. µ-CON OSC Adjustment
Settings : • Test point : TP1 (K-SCAN) and GND
• Adjustment location : L201
Method : Insert AC plug with pressing of TUNER and
DISPLAY key. Adjust L201 so that the frequency
across the test point is 194.898Hz ± 0.194Hz.
< CD SECTION >
8. Focus Gain Adjustment
Settings : • Test disc : TCD-782
• Test point : TP2 (FE), TP3 (VREF)
• Adjustment location : SFR130
Method : Play back the test disc (TCD-782, Track No.2) and
adjust SFR130 so that the voltage between the test
point (FE, VREF) becomes approx. 0mV.
– 40 –