Step 4
Refit in reverse order.
• Ensure the wiring is placed and clipped into
the correct position.
• Ensure the flow meter and water hose are in
the correct position prior to clipping the panel
into position.
• If necessary, replace the water hose
between the flow meter and the dispenser.
10.1.7

Water Dispenser Pad Replacement

Remove the module (refer to Section 8.1.6).
To remove the pad, lift the sensor pad upward.
To refit the sensor pad, ensure the retaining
clip is as shown.
Refit in reverse to above procedure.
10.1.8

Removing Water Tank

• Turn the water off at source.
• Remove all shelves.
• Remove the PC duct cover and PC Sensor from duct cover.
• Unclip the water reservoir cover from the cabinet liner.
• The reservoir is removed by sliding a flat bladed plastic putty knife or spatula on top of the
tank, and with a folding motion of the spatula, lever the tank lip from the LH side to the RH
side until the clip is lifted from the liner and the tank is removed.
Diagram A
• Remove water tubes from the tank.
Diagram A. Tank in position.
Diagram B. Fit spatula on the
RH side of lip and move to RH
side until unclipped.
Hoses are accessible once tank is removed.
35
517804E
Diagram B