Summary of Contents for Mustek PowerMust 636

  • Page 1 Line Interactive UPS PowerMust 636 (650VA), Line Int.,IEC PowerMust 848 (850VA), Line Int., IEC PowerMust 424EG (450VA), Line Int., Schuko PowerMust 636EG (650VA), Line Int.,Schuko PowerMust 848EG (850VA), Line Int.,Schuko PowerMust 1260(1200VA), Line Int., IEC/Schuko PowerMust 1590(1500VA), Line Int., IEC/Schuko PowerMust 2212(2200VA), Line Int., IEC/Schuko...
  • Page 2: Warranty And Service Information

    Please check the chapter in your manual (hardware and software) on problem solving. Additionally: Please check our website (www. Mustek.eu) regularly for updates of the software as well as Frequent Asked Questions (FAQ) . If this not solve your problem please contact your reseller for advice.
  • Page 3 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS – This manual contains important instructions for models PowerMust 636/848/424EG/636EG/848EG/1260/1590/2212 that should be followed during installation and maintenance of the UPS and batteries. • This product is specially designed for PCs and it is not recommended for use in any medical equipment, life-supporting system and other specific important equipment.
  • Page 4: Description Of Features

    o Use tools with insulated handles and wear rubber gloves and boots. o Do not lay tools or metal parts on top of batteries. o Disconnect charging source prior connecting or disconnecting batteries terminals. • When replacing batteries, replace with the same type and number of the sealed lead-acid batteries.
  • Page 5: Package Contents

    3. Package Contents You should have received the following items inside of package: 1060/1590/2212 636/848 IEC 424/636/848 EG Schuko IEC & Schuko - UPS Unit x 1 - UPS Unit x 1 - UPS Unit x 1 - Startup manual x 1 - Startup manual x 1 - Startup manual x 1 - Communication cable x 1...
  • Page 6: Audio Indicator

    interference. Do NOT operate the UPS where the temperature exceeds 0-40° C and the humidity is over 0-90 % RH. II: Connect to Utility and Charge Plug in the AC input cord to the 2-pole, 3-wire grounded wall outlet. For the best results, we suggest charging the battery at least 6 hours with no load (no electrical devices such as computers, monitors, rtc.) connected before initial use.
  • Page 7: Software Installation On Your Pc

    7. Software Installation on your PC Connected by USB to a PC or notebook, the Software enables communication between the UPS and the computer. The UPS software monitors the status of the UPS, shuts down the system before the UPS is exhausted and can remotely observe the UPS via the Network (enabling users to manage their system more effectively).
  • Page 8: Specifications

    9. Specifications Model Complete Series 1260 1590 2212 CAPACITY 450VA/240W650VA/360W 850VA/480W1200VA/600W1500VA/900W 2200VA/1200W INPUT Voltage 220 VAC Voltage Range 162~268 VAC OUTPUT Voltage 220 VAC Voltage Regulation +/-10% (Battery mode) Frequency Range 50/60Hz Frequency Regulation ±1Hz (Battery mode) Transfer Time Typical 4-8ms Waveform Modified Sine Wave PROTECTION...