7. Software Installation on your PC

Connected by USB to a PC or notebook, the Software enables communication between the
UPS and the computer. The UPS software monitors the status of the UPS, shuts down the
system before the UPS is exhausted and can remotely observe the UPS via the Network
(enabling users to manage their system more effectively). Upon AC failure or UPS battery low,
UPS takes all necessary actions without intervention from the system administrator. In addition
to automatic file saving and system shut-down functions, it can also send warning messages
via pager, e-mail etc.
Use the bundled CD and follow the on-screen instructions to install the software
WinPower.
Enter the following serial No. to install software: 511C1-01220-0100-478DF2A
After the software is successfully installed, the communication with UPS has been
established and a green icon will appear in the system tray.
Double-click the icon to use the monitor software (as above).
You can schedule UPS shutdown/start-up and monitor UPS status through PC.
Detail instructions please refer to the e-manual in the software.
Check
http://www.ups-software-download.com/index.htm
latest version of monitoring software.
8. Trouble Shooting
Symptom
No LED display on the
front panel.
Alarm buzzer beeps
continuously when AC
supply is normal.
When power failure,
back-up time is shorten.
Mains normal but LED is
flashing.
• If any abnormal situations occur that are not listed above, Please stop using the unit and
contact your reseller for advice.
• When replacing the batteries, use batteries with exactly same specifications.
• The battery must be replaced exclusively by qualified personnel (risk of shock).
Prohibit user replace battery by oneself. Please contact your reseller if need.
Possible Cause
1. Battery weak.
2. Battery defect.
3. Power switch is not pressed.
Overload of the UPS.
1. Overload of the UPS.
2. Battery voltage is too low.
3. Battery defect due to high temperature
operation environment, or improper
operation to battery.
Power cord is loose.
from time to time to get the
Remedy
1. Charge battery up to 8 hours.
2. Replace with the same type of
battery.
3. Press the power switch again.
Verify that the load matches the UPS
capability specified in the specs.
1. Remove some non-critical load.
2. Charge battery 8 hours or more.
3. Replace with the same type of battery.
Reconnect the power cord properly.