Mustek PowerMust 636 User Manual

Mustek PowerMust 636 User Manual

(600va-800va) offline, schuko
Hide thumbs Also See for PowerMust 636:

Advertisement

Quick Links

USER'S MANUAL
PowerMust 636 (600VA) Offline, Schuko
PowerMust 848 (800VA) Offline, Schuko
Uninterruptible Power Supply
EN

Advertisement

loading

Summary of Contents for Mustek PowerMust 636

  • Page 1 USER’S MANUAL PowerMust 636 (600VA) Offline, Schuko PowerMust 848 (800VA) Offline, Schuko Uninterruptible Power Supply...
  • Page 2 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS CAUTION!! Please read the following information carefully and save this manual for further reference. Disregard of these safety notes may endanger life or health, as well as the function of the equipment and the safety of your data. ...
  • Page 3  To replace the batteries by qualified service personnel. Use the same number and type of sealed lead-acid batteries.  This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen. ...
  • Page 4: System Description

    3. Red LED: Fault LED 4. All receptacles are surge protected 5. Surge protection receptacles 6. Battery power supplied receptacles Side -- 7. AC Input 8. Breaker 9. Modem/Phone Line Surge Protection PowerMust 636 (600VA) PowerMust 848 (800VA) Offline, Schuko Offline, Schuko...
  • Page 5 Installation & Operation Installing the New office UPS is as easy as following the steps shown. Be aware that the Power Switch must be kept in the “ON” position and all equipment must be plugged into the Battery Power Supplied Receptacles, otherwise, the UPS will be disabled and your equipment will not be protected during a power failure.
  • Page 6 3. Charging This unit is shipped from the factory with its internal battery fully charged. However, some energy may be lost during shipping, so the battery should be recharged before using it. Plug the unit into an appropriate power supply, then switch on UPS and allow the UPS to charge fully by leaving it plugged in for at least 8-10 hours with no load (no electrical devices such as computers, monitors, etc.) connected.
  • Page 7 5. Peripheral Equipment Connection Plug your peripheral equipment (printer, scanners, speakers) into the full-time surge protection outlets. These receptacles do not provide any power during a power failure. Note: DO NOT plug a laser printer, copier, space heater, vacuum or other large electrical device into the UPS.
  • Page 8 7. Circuit Breaker When short circuit happens, the circuit breaker will pop-up and then the UPS will shutdown automatically. After waiting for 2 minutes, please press the circuit breaker button again and the mains (AC power) will comeback. 8. Turn On/Off Press power switch 2 seconds to turn on the UPS.
  • Page 9 Chart 1 Step 2: Please remove the battery cover gently. Chart 2 Step3: After removing battery cover, gently extract the battery by disconnecting the two wires connecting to the UPS. Be sure to replace the same type of batteries and dispose of old batteries properly at an appropriate recycling facility.
  • Page 10: Specification

    Specification PowerMust 636 PowerMust 848 POWER RATING (600VA) Offline, (800VA) Offline, Schuko Schuko INPUT Sine Range of Input Voltage 170Vac~270Vac Nominal Voltage 220Vac Nominal Frequency 50H/60HZ OUTPUT Line Mode Same as input Battery Mode Step wave Line Mode Voltage Same as input voltage Battery Mode Voltage 220Vac10%...
  • Page 11 Condition Buzzer Battery normal Buzzing Per 5s Battery low Buzzing Per 1s Fault Continuous sounding Buzzing Per 0.5s Over load PROTECTION TVSS / Over load / Short Circuit Protection/Over charge PHYSICAL 600VA 800VA Dimension (DxWxH) 320*125*86(mm) 335*170*92.5(mm) Net Weight 3.1KG 4.1KG Outlets Schuko type...
  • Page 12: Troubleshooting

    Trouble Shooting If the UPS failed to operate properly, please review the following points firstly. System Possible Cause Remedy Green LED is UPS is not blinking every Connect the UPS connected 5s,but audible according to the properly to the alarm is heard installation guide mains intermittently...