10. DISASSEMBLY INSTRUCTIONS

1

INDOOR UNIT

¡ DSA-101L/DSA-121L
1. Stop the Air conditioner and disconnect the power cord from the wall
outlet.
2. Removing the Insert Grille and Frame Grille. (Fig 1~2)
!Draw up the Insert Grille and remove it.
@ Loosen two special screw for fixing the Cover Ter-Block.
# Loosen three screw at the Body.
$ Remove the Frame Grille.
3. Removing the Control Box. (Fig 3)
!Remove room and coil thermistors.
@ Disconnect the fan motor lead wire from connection at the
Control PCB.
# Disconnect the stepping motor lead wire from connection at the
Control PCB.
$ Remove the select switch from connection at the Control PCB.
% Loosen a screw for fixing ground wire.
^ Remove the Control Box
4. Removing the Drain Pan. (Fig 4)
!Disconnect the Body drain hole. (left and right Body)
@ Disconnect three hook and remove the Drain Pan.
5. Removing the Indoor Evaporator. (Fig 5~6)
!Remove three screw for fixing indoor Evaporator at the Body.
@ Remove the hook for fixing Bracket Pipe at the back of Body.
# Remove Indoor Evaporator.
6. Removing the Cross Flow Fan. (Fig 7)
!Remove set screw for fixing Motor shaft.
@ Remove Cross Flow Fan.
7. Remove Motor IDU and Bearing Plastic.