1. Once the boiler has been removed, locate the smoke unit assemby (see Figure 15).
2. Use a phillips head screwdriver to remove the inspection cover screws as seen in
Figure 16.
3. After removing the
inspection cover, inspect
the wick. If it is darkly
discolored and hard, it
should be replaced.
Replacement parts and
wick replacement
instructions are
available directly from
the M.T.H. Parts
Department phone:
(order online:
www.mth-railking.com,
e-mail:
parts@mth-railking.com
; mail: 7020 Columbia
Gateway Drive,
Columbia MD
21046-1532, FAX: 410-381-6122).
RailKing Dreyfuss Steam Engine
Figure 15
Figure 16
Smoke Unit Location
Inspection Cover
Screws