Omron FQ2-S Series User Manual page 29

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

PLC Link
The output data that is assigned is output to the output area as shown below.
Any output data that exceeds the set value of the [Max output data] (number of output data upper value)
parameter setting (e.g., 256 bytes) is discarded.
For the [Max output data] setting, refer to
Output data
Offset from first
address in output area
+0
Output data 0
(4 bytes)
+1
+2
Output data 1
(4 bytes)
+3
+4
Output data 2
(4 bytes)
+5
+62
Output data 31
(4 bytes)
+63
+64
Output data 32
(4 bytes)
+65
+122
Output data 61
(4 bytes)
+123
+124
Output data 62
(4 bytes)
+125
+126
Output data 63
(4 bytes)
+127
+128
Output data 64
(4 bytes)
+129
+160
Output data 65
(4 bytes)
+161
+162
Output data 66
(4 bytes)
+163
FQ2-S/CH User's Manual
for Communications Settings
Initial Settings for PLC Link Communications on page 122.
Assigned output data
Inspection item 0: Position X for Search
Inspection item 0: Position Y for Search
Inspection item 1: Position X 1st point for Shape Search II
Inspection item 1: Position X 30th point for Shape Search II
Inspection item 1: Position Y 1st point for Shape Search II
Inspection item 1: Position Y 30th point for Shape Search II
Inspection item 2: Position X 1st point for Shape Search II
Inspection item 2: Position Y 1st point for Shape Search II
Inspection item 2: Position X 2nd point for Shape Search II
Inspection item 2: Position X 10th point for Shape Search II
Inspection item 2: Position Y 10th point for Shape Search II
256 bytes
(Data that is
output the
first cycle.)
72 bytes
(The data that
exceeds the
set upper limit
is discarded.)
Control Methods Using an External Device