Download Print this page

Electrical Connection; Installation Requirements - Holman IRCS2-ND Manual

Inpingment conveyor toasters

Advertisement

ELECTRICAL CONNECTION

Before making any electrical connection to this unit,
check that the power supply is adequate for the voltage,
amperage and requirements stated on the rating plate.
A w i r i n g d i a g r a m i s i n c l u d e d i n t h e I n s t a l l a t i o n &
O p e r a t i o n s m a n u a l , w h i c h c a n b e d o w n l o a d e d a t
www.star-mfg.com/scripts/manuals.aspx
Disconnect the unit from the power source before installing or
removing any parts.
Be absolutely sure that the ground connection for the receptacle is
properly wired. Do not connect equipment to power without proper
ground connections. Improper grounding may result in personal
injury or fatality.
DO NOT CUT OR REMOVE THIS PLUG OR
GROUNDING PRONG FROM THE PLUG.
WARNING
CONNECT/PLUG UNIT INTO DEDICATED
A.C. LINE ONLY SPECIFIED ON THE DATA
WARNING
PLATE OF THE UNIT.
CERTAIN SURFACES ARE EXTREMELY HOT
DURING OPERATION AND CARE SHOULD
CAUTION
BE TAKEN WHILE USING THIS UNIT.
DO NOT IMMERSE OR LET THE UNIT STAND
IN WATER.
WARNING
DO NOT HOSE DOWN THE UNIT OR THE
TABLE/COUNTER IF THE UNIT IS ON THE
WARNING
TABLE/COUNTER.
KEEP AWAY FROM RUNNING WATER.
WARNING

INSTALLATION REQUIREMENTS

1. Space: 10"x29"x17.5" (width x depth x height) in
Specialty Board of Breakfast Toaster Cart
2. Electricity: 208/240 Volts, 11.5 Amps, NEMA 6-30R
Recepticale
NEMA 6-30R
NOTE: Ensure to clean the toaster properly before
using it for the first time. Refer to the Cleaning
Procedure document for cleaning instructions.
ELECTRONIC
RADIANT-IMPINGEMENT SYSTEM
.
T1
T3
T5
SAVER
TOP HEAT
BOTTOM HEAT
CONVEYOR SPEED
There are three Power Saver modes:
ON:
OFF:
AUTO ON:
The operator may adjust the level of power reduction for the saver
mode. (Note: conveyor may move slowly when in saver mode.)
Two buttons (+) and (-) are used when increasing or decreasing the
value of each programmable setting.
A red LED light located at the lower portion of the control panel label
will indicate if the value for top heat, bottom heat or conveyor speed
is being adjusted.
The Holman IRCS conveyor toaster
comes with pre-programmed factory
default settings for ALL MENU
BUTTONS.
T2
Factory default settings are as follow:
IRCS2-SBD DEFAULT
T4
Menu
Buttons
T6
T1
T2
T3
T4
ON
T5
OFF
T6
IL2711
POWER SAVER SWITCH
Unit is in pre-programmed power saving setting.
Power Saver mode is turned off.
Power Saver turns on when there has been no activity
for a programmed length of time.
SETTINGS
Top
Bottom
Conveyor
Heat
Heat
Speed
45
87
23
8
10
90
70
99

Advertisement

loading

This manual is also suitable for: