23 electrolux electrical work
Connect the cable to the outdoor unit
1. Remove the electrical control board
cover from the outdoor unit by
loosening the screw.
2. Connect the connective cables to the
terminals as identified with their
respective matched numbers on the
terminal block of indoor and outdoor
units.
3. Secure the cable onto the control
board with the cord clamp.
4. To prevent the ingress of water, form a
loop of the connective cable as
illustrated in the installation diagram of
indoor and outdoor units.
5. Insulate unused cords (conductors)
with PVC-tape. Process them so they
do not touch any electrical or metal
parts.
Terminal block of outdoor unit
For 8k, 12k and 18k Btu models
Cover
Screw
For 24k Btu models
1 2(N) 3 4
1 2(N) 3 4
Terminal block of outdoor unit
To indoor unit
To power supply
Model A
electrical work electrolux 24
1 2(N)
L N S
1
2(N)
3
4
To indoor unit
Model B