Eco-ideal eco 1 Installation And Operating Instructions Manual

Cleanburn stove

Advertisement

Quick Links

eco
1 1 1 1
CleanBurn Stove
Installation and Operating Instructions
JINECO01 RevG 11/06/12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the eco 1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Eco-ideal eco 1

  • Page 1 1 1 1 1 CleanBurn Stove Installation and Operating Instructions JINECO01 RevG 11/06/12...
  • Page 2 Find out if you are in a Smoke Control Area by contacting your Local Authority. The Eco 1 has been fitted with a permanent stop that prevents closure of the secondary air slider. Removal of this will lead to the appliance potentially causing smoke emissions. Without the permanent stop in place the appliance is not an exempt appliance and so may leave the householder liable for a fine up to £1000.
  • Page 3: General Guidance

    ANDLING General Guidance Adequate facilities must be available for loading, unloading and site handling. It is important that your stove is correctly installed as Hunter Stoves cannot accept EMENT responsibility for any fault arising through Some types of fire cement are caustic and incorrect use or installation.
  • Page 4: D O Not Over -Fire

    Do not attempt to relight the fire until the IREGUARDS cause has been identified and corrected. Always use a fireguard in the presence of children, the elderly or the infirm. The fireguard If necessary seek professional advice. should be manufactured in accordance with BS8423 –...
  • Page 5: Fire Bricks

    RICKS The Fire Bricks, in this appliance, are factory The Fire Bricks, in this appliance, are factory Assembly fitted. The following set of photos show fitted. The following set of photos show the removal sequence that you will need to employ removal sequence that you will need to employ Instructions when servicing your Hunter Stove.
  • Page 6 Slide the base of the Side Brick towards the Slide the base of the Side Brick towards the centre of the stove and remove. move. To assemble the stove, simply reverse the To assemble the stove, simply reverse the above procedure. Rear Brick Pull the top edge of the Rear Brick forward and Pull the top edge of the Rear Brick forward and...
  • Page 7: Installation Instructions

    ONNECTION TO THE HIMNEY The chimney must be swept before connection Installation to the stove. Instructions An existing fireplace opening can be bricked up or sealed with a register plate. A short length of flue pipe of minimum 127mm HIMNEY internal diameter may then be used to connect The chimney height and the position of the the stove to the chimney.
  • Page 8: Air Supply

    combustible hearth, at least 125 mm thick (this combustible hearth, at least 125 mm thick (this Minimum Draught – 1.2mm Water Gauge 1.2mm Water Gauge may include the thickness of a solid floor). may include the thickness of a solid floor). Maximum Draught –...
  • Page 9: Commissioning & Handover

    & H OMMISSIONING ANDOVER Upon completion of the installation, allow a suitable period of time for any fire cement and mortar to dry out. A small fire may then be lit and checked to ensure the smoke and fumes are taken from the stove up the chimney and emitted safely to atmosphere.
  • Page 10: Operating Instructions

    ECONDARY Operating Secondary air is controlled via the slider above the door; it is this “Airwash” that keeps a clean Instructions and uninterrupted view of the fire. The amount of air can be increased by moving the slider to This appliance is not suitable for use in a shared the right.
  • Page 11: Notes On Wood Burning

    To burn wood, push the operating tool up and IGHTING THE TOVE away from you. We recommend that you have two or three small fires before you operate your stove to its When left in this position, air is restricted maximum heat output.
  • Page 12: Reduced Combustion

    Clean Air Act requirements The eco 1 has been recommended as suitable 1993 for use in Smoke Control Areas when burning LEAN MOKE wood logs.
  • Page 13: General Maintenance

    This appliance should not be used as an LASS ANEL incinerator. Clean the glass panel when cool with Hunter Stoves glass cleaner. No liquid fuels should be burnt on this appliance. Highly abrasive substances should be avoided as these can scratch the glass and make Should any difficulties arise over fuel quality or subsequent cleaning more difficult.
  • Page 14: Chimney And Flueways

    condition, a replacement rope kit may be This is due to a reduction in the pigment used in ordered from the Hunter Stoves spares range. the manufacture of the product and no cause for concern. HIMNEY AND LUEWAYS Troubleshooting It is important that the chimney, flueways and any connecting flue pipe are swept regularly.
  • Page 15: Spares Information

    Spares Information OOR SPARES Top Hinge Pin (Eco02/011) Single Door (HEC05/001) Door Hinge (Eco02/003) Door Handle Assembly (Eco02/ARRT/006) Door Glass (Eco02/010) Slider Knob (HCE06/059) Door Cover Bottom Hinge Pin (HEC05/002) (Eco02/012) Glass Clip (HHR08/046) Glass Gasket Glass Clip Screw (Eco02/015) (FSJM05008SS) Door Slider Rope Sealing Kit...
  • Page 16: Body Assembly

    SSEMBLY PARES Flue Gasket (CH05/042) Baffle (HHC05/007) Rear Brick Tertiary Air Bar (HH04/109) (HH04/105) Riddling Support (HH04/022) Side Brick (HHC05/009) Riddling Bar (upper) (CNS06/002) Catch Bar (Eco02/014) Riddling Bar (lower) (CNS06/001) Ash Pan (Eco01/003) Cam Bar Operating Tool (HH04/015) (HFR07/040) JINECO01 RevG 11/06/12...

Table of Contents