Balanced flue system
Connection to a room sealed balanced flue
concentric system 60/100 mm
Room sealed balanced flue / duct sizing through calculation
according to EN 13384 or country-specific standard as at-
mospheric pressure system with an inlet pressure = 0 Pa
Connection to a chimney;
ventilation air directly via the boiler or through a horizontal
concentric supply line (open flue)
concentric system 60/100 mm
Room sealed balanced flue / duct sizing through calculation
according to EN 13384 or country-specific standard as at-
mospheric pressure system with an inlet pressure = 0 Pa
Connection to the flue and ventilation air through an external
wall or roof (balanced flue) system 80/80 mm
Connection to the flue in a duct and ventilation air through an
external wall (balanced flue) system 80/80 mm
Room sealed balanced flue / duct sizing through calculation
according to EN 13384 or country-specific standard as at-
mospheric pressure system with an inlet pressure = 0 Pa
Boiler CGG-1K
Calculated
length A+B
24
≤ 2 m
28
≤ 2 m
Boiler CGG-1K
Calculated
length A+B
24
≤ 3 m
28
≤ 2 m
Boiler CGG-1K
Calculated
length A+B+C+D
24
≤ 13 m
28
≤ 12 m
Boiler CGG-1K
Calculated
length A+B+C+D
24
≥ 2 m / ≤ 25 m
28
≥ 2 m / ≤ 25 m
25
20
15
10
admissible range
5
0
0
5
10
Flue gas butterfly
orifice plate no. Ø
1 (38,0 mm)
2 (39,8 mm)
Flue gas butterfly
orifice plate no. Ø
1 (38,0 mm)
2 (39,8 mm)
Flue gas butterfly
orifice plate no. Ø
39,8 mm
42,5 mm
Flue gas butterfly
orifice plate no. Ø
39,8 mm
42,5 mm
15
20
C + D
25
13