Table 6-3 Controller Module Temperature Sensors (Continued)
Description
Onboard Temperature 3
(Capacitor Temperature)
CM Temperature
When a power supply sensor goes out of range, the Fault/ID LED illuminates amber
and an event is logged to the event log.
Table 6-4 Power-and-Cooling Module Temperature Sensors
Description
Power Supply 1 Temperature
(power-and-cooling module 0)
Power Supply 2 Temperature
(power-and-cooling module 0)
To view the controller enclosure's temperature status, in RAIDar, as an Advanced
Manage user:
Select Monitor > Status > Advanced Settings > Temperature Status.
For more information see RAIDar help or the reference guide.
76
R/Evolution 2000 Series Troubleshooting Guide • May 2008
Normal
Warning
Operating
Operating
Range
Range
0–70° C
None
<=5 ° C,
5–50° C
>= 50 ° C
Normal Operating Range
0–80° C
0–80° C
Critical
Shutdown
Operating
Values
Range
None
None
<=0 ° C,
None
>= 55 ° C