Specifications
LCD display
Resolution
AC Voltage range
ACV frequency range
DC Voltage range
Accuracy
Range selection
Max measuring current
Response time
Input Impedance
Continuity test
Overvoltage protection
Low impedance test
LCD enable input voltage
Operation time:
Power supply
Battery life
Operating Temperature
Storage Temperature
Operating Humidity
Safety
Approvals
Dimensions
Weight
Copyright © 2012 Extech Instruments Corporation (a FLIR company)
All rights reserved including the right of reproduction in whole or in part in any form.
1999 counts (3-1/2 digits) with bargraph and backlight
1 Volt
0 to 480V
50/60Hz
0 to 690V
ACV ±(1.5%rdg + 5d); DCV ±(1.0%rdg + 3d)
Automatic
≤1.0mA (400VAC); ≤1.5mA (690VDC)
Updates 2-3 times/sec
1MΩ (approx)
Range 0 to 200kΩ, guaranteed on < 50kΩ; <5µA test current
480VAC/690VDC
12-250VAC/DC; impedance <6kΩ;
>4.5V AC/DC
5s<250V AC/DC
2 x "AAA" 1.5V alkaline batteries
Approx. 8 hours continuous use typical
o
-10 to 55
C (14 to 131
o
-30 to 60
C (-22 to 140
10 to 85% RH (non-condensing)
This meter is intended for origin of installation use and protected,
against the users, by double insulation per EN61243-3 and
EN61010-1 to Category IV 600V and Category III 600V; Pollution
Degree 2.
CE, IP64
240 x 78 x 40mm (9.4 x 3 x 1.6")
260G (9.2oz)
www.extech.com
7
o
F)
o
F)
VT30-E-EU-EN-V5.0-3/12
Need help?
Do you have a question about the VT30-E and is the answer not in the manual?