Glow-worm 30ci Instructions For Use, Installation & Servicing page 10

Fanned flue boilers
Table of Contents

Advertisement

Event Review
To review the programs at any time, press Prog. key. Events
will appear in the order they were entered with repeated
presses of the Prog. key. After all events have been reviewed,
the blank display will appear to allow entering another event.
Another press of the Prog. key will display the number of free
events available, such as Fr 16 if 4 events have been entered.
Manual Override
While in the Run Mode, pressing the
the current mode; ON to OFF or OFF to ON. The symbol
appears in the display to indicate a temporary override.
At the next scheduled switching time, automatic control
resumes, eliminating the override.
CONTINUOUS OPERATION: While in the Run Mode, press
the
key twice to turn the output to permanently ON.
symbol appears in display.
Pressing the
key three times will turn the output OFF
permanently.
symbol appears in display.
To terminate a continuous override, press the
appears in the display.
Changing an Event
Select the event to be changed with the Prog. key. A new set
of days may be selected with the Day key just as in initial
programming.
Hours and minutes can be changed with the h and m keys.
Press Prog. or
key to store the new programme.
Deleting an Event
To delete only one or a few events: Press Prog. key until the
desired program is displayed.
Press m key to :59 and press once more to blank out.
Press h key to 11PM and press once more to blank out.
Press
key, display will flash for several seconds and then
enter the Run Mode. Using the reset key will delete ALL events,
the time of day, and day of the week.
4000123434-2
Supplied By www.heating spares.co Tel. 0161 620 6677
Programmer Instructions for Use
key once will reverse
key until
10
Troubleshooting
PROBLEM: Days are flashing, pressing any key does nothing
except
key turns output ON and OFF.
SOLUTION: Time of Day and Day of Week have not been set.
See "SETTING THE TIME"
This is the condition after a reset. If the timer is found in this
condition after it has been installed, programmed and operating
for a while, it may indicate that interference has disrupted the
microprocessor causing a loss of programme information.
A second, but very unlikely cause of loss of programme is a
power failure with the backup capacitor low or dead. Check by
disconnecting power and monitoring how long the capacitor
keeps the time of day in the display. Typically, the capacitor will
maintain the time and programmes for 4 days, but not more
than 5 days.
PROBLEM: Time of day was set while holding the
down, but days are still flashing.
SOLUTION: Current day of week was not set while holding
down
the key. See "SETTING THE TIME"
PROBLEM: It is 10AM and an ON event for 8AM was entered,
but the output is not ON. Display shows the
symbols.
SOLUTION: After programming, the timer does not "look back"
to determine if it should be ON. Press the
override) to turn the output ON;
The timer will assume automatic operation at the next
programmed event.
PROBLEM: An event for 8AM Monday through Friday was
entered,
but it will not accept it and
SOLUTION: The ON
or OFF
of the program. ON or OFF must be selected.
key
and
key (temporary
appears in display.
is flashing.