Harbor Freight Tools PacificHydroStar Owner's Manual & Safety Instructions

Advertisement

Owner's Manual & Safety Instructions
Save This Manual
inspection, maintenance and cleaning procedures. Write the product's serial number in the back of the manual
near the assembly diagram (or month and year of purchase if product has no number). Keep this manual and
the receipt in a safe and dry place for future reference.
Do not use for
potable water.
Email our technical support at: productsupport@harborfreight.com
REV 14l
When unpacking, make sure that the product is intact
and undamaged. If any parts are missing or broken,
please call 1-888-866-5797 as soon as possible.
Copyright
2014 by Harbor Freight Tools
©
No portion of this manual or any artwork contained herein may be reproduced in
any shape or form without the express written consent of Harbor Freight Tools.
Diagrams within this manual may not be drawn proportionally. Due to continuing
improvements, actual product may differ slightly from the product described herein.
Tools required for assembly and service may not be included.
Keep this manual for the safety warnings and precautions, assembly, operating,
Visit our website at: http://www.harborfreight.com
. All rights reserved.
®
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.
ITEM 62508

Advertisement

Table of Contents
loading

Summary of Contents for Harbor Freight Tools PacificHydroStar

  • Page 1 No portion of this manual or any artwork contained herein may be reproduced in Failure to do so can result in serious injury. any shape or form without the express written consent of Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing SAVE THIS MANUAL.
  • Page 2: Fluid Type

    Before start-up, note the following: The pump can be connected to any shock-proof plug which has been installed according to regulations. The plug must have a supply voltage of 120 VAC at 60 Hz. CAUTION This pump has been evaluated for use with clear water only. WARNING IMPORTANT! For your own safety –...
  • Page 3: Specifications

    Specifications Electrical Rating 120VAC / 60Hz / 5A Inlet / Outlet Diameter 1" - NPT Maximum Pressure 50 PSI Maximum Flow 550 GPH Maximum Suction Lift Maximum Delivery Height 110' Maximum Water Temperature 95°F (35°C) Maximum Ambient Temperature 104°F (40°C) Power Cord Length 3065430 Item 62508...
  • Page 4 Functions Power Cord (not shown) Priming Plug Outlet Inlet Figure A Page 4 For technical questions, please call 1-888-866-5797. Item 62508...
  • Page 5: Installation

    Installation TO PREVENT SERIOUS INJURY AND ELECTROCUTION: Do not allow Pump to get wet. Do not use for potable water. This item is not lead-free. No person may use any pipe, any pipe or plumbing fitting or fixture, any solder, or any flux, in the installation or repair of any public water system or any plumbing in a residential or nonresidential facility providing water for human consumption that is not lead-free.
  • Page 6: Permanent Installation

    Permanent Installation Note: Use fixed pipeline. 1. When planning Pump location, select a clean, level, 4. Incorporate the following items into the plumbing: dry location indoors or outdoors, close to the water See “Figure D”. supply, with a 120V GFCI protected outlet nearby. a.
  • Page 7: Temporary Installation

    Temporary Installation Note: Use non-collapsible hose on Inlet. 2. Attach hoses to Inlet and Outlet. 1. When planning Pump location, select a clean, level, 3. Attach Check Valve to Inlet hose. dry location indoors or outdoors, close to the water 4.
  • Page 8: General Operation

    Operation Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product. After reading these instructions, consider the following points before starting the pump: 1.
  • Page 9: Troubleshooting

    Troubleshooting Problem Possible Causes Likely Solutions Motor will 1. Cord not connected. 1. Check that cord is plugged in. not start. 2. No power at outlet. 2. Check power at outlet. If outlet is unpowered, turn off tool and check circuit breaker. If breaker is tripped, make sure circuit is right capacity for tool and circuit has no other loads.
  • Page 10: Maintenance

    Maintenance TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION: Unplug the Pump from its electrical outlet before performing any inspection, or cleaning procedures. TO PREVENT SERIOUS INJURY FROM PUMP FAILURE: Do not use damaged equipment. If abnormal noise or vibration occurs, have the problem corrected before further use.
  • Page 11: Parts List And Diagram

    Parts list and Diagram Item Description Item Description Shipping Plug End Plate Bolt (M5 x 40) Mechanical Bolt Pump Housing Cord Clip Impeller Gasket Mechanical Seal Cord Clip O-Ring Wave Spring Bolt (M5 x 20) Mechanical Bolt Support Screw Cap Waterproof Ring Seal Washer Circlip...
  • Page 12: Please Read The Following Carefully

    Limited 90 Day Warranty Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase.

Table of Contents