Lincoln Electric INVERTEC SVM161-A Service Manual page 46

Lincoln electric welding system user manual
Table of Contents

Advertisement

F-6
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
Error code "E20", "E24", or "E25" is
flashing on the digital display.
The machine functions normally
except the cooling fan does not
operate.
No High Frequency when the torch
trigger is pulled and the machine is
in the TIG mode.
Error code "E14" is flashing of the
digital display
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
TROUBLESHOOTING AND REPAIR
POSSIBLE AREAS OF
MISADJUSTMENT(S)
FUNCTION PROBLEMS
1. Any one of these codes indicates
a memory error.
1. Check for obstructions that could
prevent the fan from turning.
1. Make sure the HF is in the active
mode. See the Set-up Menu in
this manual.
1. This is an indication that the out-
put inductance is too high.
CAUTION
INVERTEC® V205-T AC/DC™
RECOMMENDED
COURSE OF ACTION
1. The Control/Display Board is
faulty. Replace.
1. Check the fan fuse F3 located on
the Bus Board Replace if faulty.
2. Perform the Bus Board Test.
3. The Main IGBT Inverter Board
May be Faulty.
Perform the
Main IGBT Inverter Board Low
Voltage Supply Test.
1. Check fuse F2 on the Bus Board.
2. Check for 385VDC at Test
Points 9 and 20. See the Main
IGBT Inverter Board Test.
3. Perform the Control/Display
Board Test.
4. The HF board may be faulty.
Replace.
1. Check for excessive welding
cable length.
2. The Main IGBT Inverter Board
may be faulty.
3. The Superimposition Board may
be faulty.
4. The Control/Display Board may
be faulty.
F-6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Invertec v205-t ac/dc

Table of Contents