Heat Exchanger Replacement - Electrolux BEVERAGE CENTER II Service Manual

Table of Contents

Advertisement

10.Place cap tube in new evaporator and weld in place.
Put suction line in new evaporator and weld in place.
(See Figure 3.)
11.Using sharp knife, cut along a seam on heat shield,
from hole for lines to right edge of shield. Slide
shield off suction line assembly.
12.Push evaporator back in place and connect heater.
Mount limiter on evaporator.
13.Replce Drier-Filter. Pump down and recharge
system.
14.Allow product to run and make sure refrigerant is
circulating.
15.Reinstall evaporator cover and compartment cover, if
so equipped.
HEAT EXCHANGER KIT REPLACEMENT
The original heat exchanger (Suction Line & Cap Tube
Assembly) in this refrigerator is enclosed in the insulation
between the liner and the cabinet at the back. Because
of this, you can not remove the original part. It will be
necessary to run a new heat exchanger down the back
of the refrigerator and bypass the internal heat exchanger.
This kit contains:
1 Heat Exchanger
1 Drier-Filter
1 Armor Flex
2 Tape
1 Instruction Sheet
To replace the Heat Exchanger:
1. Recover refrigerant from sealed system.
2. Remove evaporator cover and disconnect defrost
heater and limit thermostat wires.
3. Cut heat exchanger off flush with liner.
(See Figure 1.)
Disconnect the defrost heater and
limit thermostat. (Do not remove
from evaporator.) Lift evaporator
off supports.
Remove evaporator and save for
reuse.
FIGURE 1
12 Screws
1
Cover, Upper
1
Cover, Lower
1
Package Permagum
Cut suction line
off at liner.
4. Recover evaporator. (You do not need to remove
defrost heater.)
5. Using ¼ drill bit, drill hole through the cabinet from
inside at location shown in Figure 2.
6. Using ½" drill bit, open hole drilled in Step 5 to ½"
from back of product. See Figure 2.
7. Remove stubs of old heat exchanger from
evaporator and install new heat exchanger into
evaporator.
8. Push heat exchanger through hole in cabinet (see
Figure 3) and set evaporator in place.
9. Excess cap tube can be folded from bottom so it is
alongside suction line and will be inside Armor Flex.
Slide Armor Flex over line covering excess cap tube
until cover is against hole at back of cabinet. (See
Figure 3.)
Push heat exchanger through hole in cabinet.
Install armor flex
over heat
exchanger.
FIGURE 3
41
Drill ¼ hole in center of
opening.
FIGURE 2
Open hole up to ½ inch
from back of the
cabinet.

Advertisement

Table of Contents
loading

Table of Contents