To Remove Refrigerator Light Socket

1. Disconnect electrical supply to refrigerator.
2. Remove four screws securing housing to top of
refrigerator compartment. (See Figure C6.)
3. Unplug molex connector.
4. Unscrew light bulb.
5. Disconnect two wires to light socket. (Yellow/Red
and Blue wires)
6. Squeeze in on tabs on light socket and push through
Control Box.
6. Reverse procedure to complete repairs.
To Remove Freezer Light Socket (See Figure C8)
1. Disconnect electrical supply to refrigerator.
2. Remove freezer section shelves and baskets.
3. Remove two screws securing ice cube tray holder
or ice maker (some models).
4. Disconnect ice ice maker molex plug from wiring
harness connector mounted on back freezer wall in
upper left hand corner (some models).
5. Remove fan access cover by pressing in on both
sides (top and bottom) of access cover and pull
forward.
6. Remove light shield by pressing in on tab on bottom of
shield and pulling forward.
7. Disconnect three wires to lamp socket. (Yellow/
Red and two piggybacked Blue wires)
8. Push in on tabs on light socket and push through
coil cover.
6. Reverse procedure to complete repairs.

LIGHT SWITCH

The light switch is a door activated, single-pole, single-
throw switch (SPST). (See Figure C10)
When the door is closed, the light circuit is open (OFF).
Push on terminal connectors secure the wiring harness
leads to the switch terminals.
Figure C9
To replace the switch, pry the switch out of its mounting,
disconnect the wire leads, and replace.

DAMPER CONTROL

The Damper Control regulates the freezer compartment
temperature. The Damper Control consists of the Freezer
Control Knob and Damper.
When the Freezer Control Knob is moved from a WARMER
to a COLDER setting, the Damper moves, keeping more
air generated by the Freezer Fan Assembly inside the
freezer compartment.
When the Freezer Control Knob is moved from a COLDER
to a WARMER setting, the Damper moves to allow more
air into the refrigerator section.
PERIMETER HOT TUBE / MULLION HEATER
To reduce the possibility of condensation forming on the
exterior of the cabinet and between doors in high humidity
areas, units are equipped with a perimeter hot tube and/
or a center mullion heater.
The perimeter hot tube, which is part of the refrigeration
system, is used instead of an electric perimeter heater.
Refer to Refrigeration Section E for details.
EVAPORATOR FAN & MOTOR ASSEMBLY
The fan and motor assembly is located behind the
freezer compartment air duct directly above the evapora-
tor in the freezer compartment.
The fan is a suction type, pulling air up through the
evaporator and blowing it through an air duct behind the
liner into the food compartment through the freezer
control baffel.
The freezer compartment fan motor is wired in series with
the control thermostat and the contacts of the defrost timer,
and operates when the control thermostat contacts are
closed, except during the defrost cycle.
On current production models, the fan blade is not adjust-
able and is designed to be pressed onto the motor shaft until
it bottoms out against the stop at the front of the fan blade.
To Remove Freezer Fan Motor (See Figure C11)
NOTE: When replacing the fan blade, press the
blade onto the motor shaft until the blade bottoms
out on the shaft.