4. Remove evaporator fan access cover (1 screw)
5. Remove evaporator coil cover (4 screws).
NOTE: Ensure that you disconnect the Green/
Yellow ground wire connected to the drain trough.
6. Disconnect leads (2) to defrost heater.
7. Pull evaporator away from insulator so bottom of
evaporator is free and pointing towards you.
NOTE: The defrost heater is positioned in between
the evaporator coils. It is a very snug fit.
8. Grab heater from bottom and pull free of evaporator.
It is very snug so you will need to use a little force.
9. Check resistance of defrost heater using multimeter.
(Refer to data sheet on page 31)
10.Replace defrost heater if resistance readings are
out of range.
11.Reassemble in reverse order.