11. Install new compressor in exact same manner as
original compressor.
12. Reform both suction and discharge lines to align with
new compressor. If they are too short, use additional
lengths of tubing. Joints should overlap 0.5" to
provide sufficient area for good solder joint. Clean
and mark area where tubing should be cut. Cut
tubing with tubing cutter. Work as quickly as pos-
sible to avoid letting moisture and air into system.
NOTE: If low-side process tube is too short, silver
solder four inch piece of tubing onto process tube
at this time.
13. Solder all connections according to soldering
procedure outlined above.
14. Remove original filter-drier.
CAUTION: DO NOT unbraze old filter-drier
from system. This will vaporize and drive
moisture from desiccant back into system.
The old filter-drier should be cut out of
system.
15. Install new filter-drier at condenser outlet.
16. Evacuate and charge system using recommended
procedure described under Evacuating and
Recharging on pages 44-45.
17. Reconnect compressor terminal leads in
accordance with refrigerator wiring diagram.
18. Reassemble unit.