FAUCET ASSEMBLY INSTALLATION

Attach faucet knob (9) to Faucet & Shank Assembly (6).
Slip the Faucet & Shank Assembly (6) through the black
plastic collar (7) (flat side toward door), Facade (3), and
hole in door.
Thread on the large Shank Nut (8) and tighten until snug,
using an adjustable wrench. DO NOT over tighten.
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
Replacing the faucet knob (9) with a longer knob is not
recommended. This may interfere with the opening of the
freezer door causing beverage spillage and/or damage to
the faucet assembly and door.
SUMP AND DRIP TRAY ASSEMBLY INSTALLATION
Remove bottom mounting screw.
Align the two notched mounting tabs on back of sump (1)
with upper mounting screws in door and push up.
Install bottom mounting screw through slot and tighten.
FIRST STEPS (continued)

SUMP VALVE INSTALLATION

Place one rubber washer (5) on threaded end of sump
valve (4).
Slip sump valve with washer through hole in bottom of sump
(1).
Place remaining rubber washer (5) over threaded end of
sump.
Thread plastic nut (5) onto threaded end of sump valve and
tighten until snug.
Make sure knob on valve is located to front for proper
operation.
Place Drip Tray (2) onto the Sump (1).

REGULATOR INSTALLATION

Check to ensure plastic washer is inside the hex nut.
N O T E
N O T E
N O T E
N O T E
N O T E
If the plastic washer is missing, please call Electrolux Consumer
Services at 1-800-944-9044 or your part distributor for the washer
Fasten the CO
the regulator to the right of the tank.
Tighten the hex nut securely. DO NOT over tighten. Over
tightening may damage the gasket in the nut of the regulator.
1 2
regulator (10) to the CO
2
2
.
canister (16). Place

Advertisement