Inground Inline Installation - Sani king PERFORM-MAX 910 Instruction Manual

Pool sanitizer
Table of Contents

Advertisement

TOOLS NEEDED
Wrench
Hacksaw
MATERIALS NEEDED:
Pipe Thread
Sealant
P IP E
PVC
Cement
PVC
CEMENT
Two 2" Threaded
X 2" or 1 1/2" Slip
PVC Bushings
(not included)
RECOMMENDED:
Check Valve
Rainbow
#172288
#10 X 1 1/4" Phillips Pan
P O O
L S A NI
TIZER
Use Phillips pan head
screws through the
mounting holes at the
Perform-Max base to
secure the Perform-Max
into a treated wood base.
Inground, Inline Installation – Model 940
Install after all equipment and as far as possible from heater.
M
Do NOT install an inline
Perform-Max off-line as this
Perform-Max is different than
an off-line unit.
1.
P IP E
P O O
L S A NI
TIZER
Following pipe thread
sealant directions, brush
sealant onto Perform-Max
threads in both ports.
P O O
L S A NI
TIZER
CEMENT
4.
Following PVC cement
directions brush PVC
cement on to ends of pipe
and the inside of bushings.
M
Can be installed with the
water flow in either direct-
ion due to its bi-flow valve.
2.
Brush sealant on the
threads of both bushings.
DO NOT USE TEFLON TAPE as
the threads
on these units
are not suitable
for this use and
leaking or bushing
failure could result.
PO OL
SA NIT IZER
PVC
5.
Insert PVC pipe into
bushings. Hold in place
5 to 10 seconds to bond.
COPPER PIPE
Do NOT install in copper pipe
as chemical corrosion occurs.
M
M
12" to 15"
3.
P O O L
S AN ITI ZER
P IP E
T H R
EA D
S E A LAN T
Screw a bushing
into each port of
Pool Sanitizer and
hand tighten.
Completely tighten
turning 1 to 2
revolutions
with wrench.
DO NOT
OVERTIGHTEN.
6.
Isolating the Perform-Max by
installing a corrosion
resistant check valve or
creating a plumbing loop is
recommended to protect the
equipment and prevent
possible discoloration of pool
surface.
12" to 15"
Leave 12" to
15" above and
around
Perform-Max
to allow room
for easy
refilling.
M
7

Advertisement

Table of Contents
loading

Related Products for Sani king PERFORM-MAX 910

Table of Contents