Heat Pump Dimensions - Rheem MPi 551 Series Owner's Manual And Installation Instructions

Air sourced heat pump water heater
Hide thumbs Also See for MPi 551 Series:
Table of Contents

Advertisement

ASSEMBLY PROCEDURE
Warning: The heat pump must be assembled, plumbed and filled with water prior to power being
connected and switched on.
The following procedure should be followed to properly place the heat pump module in position and connect
to the storage tank:
Heat Pump Storage Tank: Remove all packaging including the carton base from the heat pump
1.
storage tank and position in its intended location, supported by a stable base.
The water connections may be on either the left or right hand side and should be parallel to the wall.
The storage tank must be positioned at least 100 mm from the wall. If a minimum clearance of 100 mm
is not allowed for, the heat pump module will not be able to be completely connected to the storage tank.
The storage tank must also be positioned such that when the heat pump module is in position, there is a
clearance of at least 300 mm perpendicular from both the front air inlet louvres and the outlet grille to
any wall or obstruction.
and allow for at least 300 mm ventilation clearance (refer table on page 24 for dimensions)
2.
Lower Front Cover: Remove the two screws securing the lower front cover to the storage tank.
Remove the lower front cover from the storage tank.
from lower front cover
Power Cable: Withdraw the power cable, housed behind the lower front cover, from the opening.
3.
AIR INLET
100
H
TPR
VALVE
K
Step 1 – position storage tank at least 100 mm from the wall
HOT
OUTLET
A
D
COLD
INLET
E

HEAT PUMP DIMENSIONS

325 & 410 INTEGRATED
Step 2
remove screws
HEAT PUMP AND TANK ASSEMBLY
WALL
AIR
OUTLET
574
AIR
VENTILATION
INLET
CLEARANCE
CONDENSATE DRAIN
275
B
AIR INLET
VENTILATION
CLEARANCE
AIR
OUTLET
544
ELECTRICAL
CONNECTION
F
withdraw the power cable
27
C
1018
872
SK6753 - 1 A4
REV CD 04/13
Step 3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mpi 554 series

Table of Contents