Chimney Termination Requirements; Outside Air Requirements - Travis Industries 1750 Owner's Manual

Hide thumbs Also See for 1750:
Table of Contents

Advertisement

12
Stove Installation

Chimney Termination Requirements

Must have an approved cap (to prevent water from entering)
Must not be located where it will become plugged by snow or other material
Must terminate at least 3' above the roof and at least 2' above any portion of the roof within 10' (see
Figure 6)
Slanted Roofs
Chimney must
extend 3'
above the roof
Flat Roofs
Chimney must
extend 3'
above the roof

Outside Air Requirements

Required for mobile homes & in certain localities (check with building officials)
Must not be drawn from an enclosed space (garage, unventilated crawl space)
Requires the optional outside air connector or pedestal.
Pedestal may be used to
direct air from below the
stove. See the pedestal
instructions for complete
details.
Air may be drawn from a ventilated
crawl space or use an air duct.
© Travis Industries
When using outside air, find a location where the chimney and
outside air hole do not interfere with structural members of the home.
100-01179
(for qualified installers only)
Chimney must extend 2'
above any portion of the roof
within 10' of the chimney
Chimney must extend 2'
above any portion of the roof
within 10' of the chimney
The pedestal has an air
opening for use with the
outside air connections.
This allows air to be
drawn from behind the
pedestal.
Outside Air
Connector
Outside air entrance must be placed so
it does not become blocked by snow.
Figure 6
Figure 7
4060926

Advertisement

Table of Contents
loading

Table of Contents