Service Parts Replacement; Glass Replacement - Door Assembly; Blower Replacement - Quadra-Fire 27I-ACC Owner's Manual

2700 insert acc wood insert automatic combustion control (acc)
Hide thumbs Also See for 27I-ACC:
Table of Contents

Advertisement

27I-ACC
5

Service Parts Replacement

A. Glass Replacement - Door Assembly
(Replace with 5mm ceramic glass only)
1.
Ensure that the fi re is out and the appliance is cool to
the touch.
2.
Protect a table or counter top with padding or towels.
Protect your hands and wear gloves to prevent injury.
3.
Remove the door with the broken glass by lifting the door
up and off of the hinges.
4.
Lay door face down on a table or counter making sure
the handle hangs over the edge so the door lays fl at, on
a soft surface.
5.
Remove the screws from each glass retainer and remove
the glass. (If screws are diffi cult to remove, soak with
penetrating oil fi rst).
6.
Center the glass with edges evenly overlapping the
opening in the door, (i.e. same space top and bottom,
left and right sides).
7.
Replace the glass retainers. Be careful not to cross
thread the screws.
8.
Tighten each retainer just a few turns until each is
secured. Check again for centering of glass in door
frame. Continue to tighten each retainer alternately, a
few turns at a time, until the glass is secure. DO NOT
OVERTIGHTEN - can cause glass to break.
9.
Replace the door on the appliance.
Quadra-Fire appliances are equipped with ceramic super
heat-resistant glass, which can only be broken by impact
or misuse.
WARNING! Risk of Fire or Injury!
Use only glass that is specifi ed in the manual, DO NOT
replace with any other material. Glass breakage will occur.
CAUTION!
Handle glass with care.
• Inspect the gasket to ensure it is undamaged.
• Do NOT strike, slam or scratch glass.
• Do NOT operate appliance with glass & door assembly
removed.
• Do NOT operate with glass cracked, broken or
scratched.
CAUTION
Shock Risk.
• Do NOT remove grounding prong from plug.
• Plug directly into properly grounded 3 prong
receptacle.
• Route cord away from appliance.
• Do NOT route cord under or in front of appliance.
22
B. Blower Replacement
1. Using a 5/32 Allen wrench, remove 4 blower housing
mounting bolts and slide assembly out. Figure 22.1.
2. Disconnect the wires from the blower.
3. Using a Phillips head screw driver, remove 4 screws.
Figure 22.2.
4. Remove blower from the blower housing assembly.
5. Install new blower and secure with the same 4 screws.
6. Re-connect the wires to the blower.
7. Slide the assembly back into position under the ash lip and
secure with the 4 mounting bolts.
Remove Bolts and Slide
Blower Assembly Out
Figure 22.1
Remove 4 Screws
& Remove Blower
from Housing
Figure 22.2
7046-191C
April 30, 2015

Advertisement

Table of Contents
loading

Table of Contents