Specifications
Environmental specifications
Specification
Temperature range*
Operating
Nonoperating
Relative humidity
(noncondensing)
Operating, maximum wet bulb
temperature of 28°C (82.4°F)
Nonoperating, maximum wet
bulb temperature of 38.7°C
(101.7°F)
* All temperature ratings shown are for sea level. An altitude derating of 1° C per 304.8 m (1.8° F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
Server specifications
Specification
Dimensions
Height
Depth
Width
Weight
Power supply specifications
The server supports one HP 300 W Integrated Power Supply.
CAUTION:
Specification
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Value
10° C to 35° C (50° F to 95° F)
-30° C to 60° C (-22° F to 140° F)
10% to 90%
5% to 95%
Value
36.39 cm (14.3 in)
38.1 cm (15 in)
16.5 cm (6.5 in)
5.94 kg (13.08 lb)
Check the system and power supply input ratings before powering up the server.
Value
100 V to 240 V
50Hz to 60Hz
4 A at 100 VAC to 200 VAC
Specifications 60