Powerful Mode Operation; Economy Mode Operation - Panasonic CS-C75KE Service Manual

Hide thumbs Also See for CS-C75KE:
Table of Contents

Advertisement

S-C75KE CU-C75KE / CS-C95KE CU-C95KE / CS-C125KE CU-C125KE
8.5.
Sleep Mode Auto Operation
Cooling or Soft Dry Operation
When you press the SLEEP Mode, the following movement will
start to avoid overcooling.
• When
the
room
temperature or after 1 hour of operation, sleep shift
operation starts and the airflow volume will automatically
change to low.
• The setting temperature will be risen by 0.5°C at the start of
operation and by 0.5°C one hour later.
• The operation will stop after 8 hours.
8.6.

Powerful Mode Operation

• Purpose of this operation is to obtain the setting temperature quickly.
• When the Powerful Mode is set, the set temperature will be automatically decreased 3°C against the present setting
temperature.
This operation automatically will be running under Super High Fan speed.
• Vertical Airflow Direction:-
- In "Manual" setting, the vane will automatically swing down 10° lower than previous setting.
- In "Auto" setting, the vane will automatically swing up and down. However the lower limit will be shifted 10° downward.
• Powerful Mode will operate for 15 minutes only.
• Powerful Mode will stop if:-
- Powerful mode button is pressed again.
- Stopped by ON / OFF switch.
- Timer OFF activates.
- Economy mode button is pressed.
- Sleep mode is pressed.
- Operation mode button is changed.
8.7.

Economy Mode Operation

• Purpose of this operation is to save or reduced electrical power consumption of the room air conditioner.
• When the Economy Mode is set, the set temperature will be automatically increased 0.5°C against the preset setting
temperature. This operation automatically will be running under Random Fan speed.
(Refer operation details no. 8.9)
• Vertical Airflow Direction:-
In "Manual" or "Auto" setting, the vane will automatically change to Auto Air Swing.
• Economy Mode will stop if:-
- Economy Mode button is pressed again.
- Stopped by ON / OFF switch.
- Timer OFF activates.
- Powerful mode button is pressed.
- Auto or Manual air swing button is pressed.
- Fan Speed control button is pressed.
- Sleep Mode button is pressed ON.
- Operation Mode is changed.
temperature
reaches
the
setting
22