Problem
No AC power
No power to AC devices
Inadequate power to AC
devices
(generator running)
Continuous tripping of main
breaker
Generator will not start
No power at AC outlets
Hunter 45DS • AC Electric

Troubleshooting

Possible Cause
Main breaker(s) aft cabin
tripped or off
Shore power cord not con-
nected
Loose or disconnected wire
Breaker(s) at AC control
Center tripped or off
Shore power cord not con-
nected
Loose or disconnected wire
Electrical demand greater
than generator output
Cause of problem not cor-
rected
Battery discharged or dead
Outlet breaker in AC con-
trol center OFF
Ground fault interrupter
tripped
g
g
g
Turn breaker on or reset
Check cord, plug in if necessary
Tighten connections. See your dealer
Turn breaker on or reset
Check cord. Plug in if necessary
Check cord. Plug in if necessary
Tighten connections. See your dealer
Switch off devices
and equipment not needed
Switch PARALLEL breaker off to reduce demand
Use shore power AC line if available
Determine cause and correct problem before resetting
breaker
See your dealer if problem persists
Recharge or replace battery
Switch breaker to ON
Reset button on outlet and test
8.7