SYMPTOM
White / grey fi lm
Sulphur from fuel is being
forms.
deposited on glass, logs or
combustion chamber
surfaces.
Flames are very
Door is ajar.
aggressive.
Venting action is too great.
Main burner fl ame
Blockage in vent.
is a blue, lazy,
transparent
fl ame.
Compromised venting.
Main burner goes
Vent recirculation.
out: pilot goes out.
PROBLEM
-
-
-
-
-
-
-
-
TEST SOLUTION
Clean the glass, see "CARE OF GLASS" section
DO NOT CLEAN GLASS WHEN HOT.
If deposits are not cleaned off regularly, the glass
may become permanently marked.
Tighten door clamps if applicable.
Restrict vent exit with restrictor plate. See
"RESTRICTING VENTS" section if applicable.
Remove blockage. In extreme conditions, ice
buildup may occur on the terminal and should be
removed. To minimize this from happening again,
it is recommended that the vent lengths that pass
through unheated spaces (attics, garages, crawl
spaces) be wrapped with an insulated mylar sleeve.
Prevent sleeve from sagging. Contact your local
authorized dealer for more information.
Check venting system parameters (seal, length,
rise, etc.).
Check joint seals and installation.