Advertisement

Quick Links

1
W415-0484 / C / 10.15.07
$10.00
W415-0484 / C / 10.15.07

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the B26DFN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Napoleon B26DFN

  • Page 1 W415-0484 / C / 10.15.07 $10.00 W415-0484 / C / 10.15.07...
  • Page 2: Table Of Contents

    TABLE of CONTENTS PG 2-4 INTRODUCTION 18-19 FINISHING Warnings and Safety Precautions Door Removal & Installation Warranty Louvre Installation General Instructions Log Placement / Glowing Embers General Information Charcoal Embers Care of Glass & Plated Parts Charcoal Lumps Logo Placement 5 - 12 VENTING Venting Lengths OPTIONAL BLOWER INSTALLATION...
  • Page 3 ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL LTD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL LTD.
  • Page 4: General Instructions

    The glass thickness is 3/16". Use only re- • The appliance is not approved for installation in a bedroom or placement glass available from your Napoleon® dealer. DO bathroom unless the unit is a direct vent sealed combustion NOT SUBSTITUTE MATERIALS.
  • Page 5: Venting

    Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp or For optimum performance it is recommended that all horizontal American Metal Amerivent venting components. runs have a 1 inch rise per foot when using Napoleon® flexible For Simpson Dura-Vent, Selkirk Direct Temp and American Metal vent components.
  • Page 6: Minimum Air Terminal Location Clearances

    MINIMUM AIR TERMINAL LOCATION CLEARANCES FIGURE 2 W415-0484 / C / 10.15.07...
  • Page 7: Typical Minimum And Maximum Vent Lengths

    TYPICAL MINIMUM AND MAXIMUM VENT LENGTHS NOTE: When terminating vertically, the restrictor plate W500-0205 must be installed. Refer to Restricting Vertical Vents. FIGURES 3 a-c SPECIAL VENT INSTALLATION PERISCOPE TERMINATION Use the GD401 periscope kit to locate the air termination above grade.
  • Page 8: Horizontal Termination

    VENTING APPLICATION FLOW CHART VERTICAL HORIZONTAL TERMINATION TERMINATION Vertical rise Vertical rise Vertical rise Vertical rise is less than is less than is equal to or is equal to or horizontal h o r i z o n t a l g r e a t e r g r e a t e r than...
  • Page 9 DEFINITIONS ELBOW VENT LENGTH VALUES for the following symbols used in the venting calcula- feet inches tions and examples are: 1° 0.03 > - greater than 15° 0.45 > - equal to or greater than 30° 11.0 < - less than 45°* 1.35 16.0...
  • Page 10 HORIZONTAL TERMINATION when (H ) > (V Example 2: Simple venting configuration (only one 45º and 90° elbow) FIGURE 8 90° See graph to determine the re- 90° FIGURE 7 quired vertical rise V for the re- 90° quired horizontal run H 90°...
  • Page 11 VERTICAL TERMINATION when (H ) < (V Example 3: Simple venting configurations FIGURE 9 FIGURE10 90° 90° 45° 45° 90° See graph to determine the required vertical rise V for the required horizontal run H = 5 ft = 10 ft = 5 + 10 = 15 ft = 3 ft = 2.5 ft...
  • Page 12 VERTICAL TERMINATION when (H ) > (V = 1 ft Simple venting configurations = 1.5 ft = 1 + 1.5 = 2.5 ft = 6 ft FIGURE 11 = 2 ft = 6 + 2 = 8 ft = .03(one 45º elbow + three 90º elbows - 135º) = .03(45 + 90 + 90 + 90 - 135) = 5.4 ft = 8 + 5.4 = 13.4 ft = 13.4 + 2.5 = 15.9 ft...
  • Page 13: Installation

    Napoleon® dealer. See within the opening. Place the firestop bottom against the Accessories to order the firestop top and secure the two together. Adjust the specific kit required.
  • Page 14: Using Flexible Vent Components

    USING FLEXIBLE VENT COMPONENTS Use only approved aluminum flexible liner kits marked: Black high temp Mill Pac with the exception of the fireplace exhaust flue collar which must be sealed using Mill Pac (not supplied). Do not allow the inside liner to bunch up on horizontal or vertical runs and elbows.
  • Page 15: Fireplace Vent Connection

    5. Remove nails from the shingles, above and to the sides RESTRICTING VERTICAL VENTS of the chimney. Place the flashing over the air terminal and Vertical terminations may display a very active flame. As slide it underneath the sides and upper edge of the this appearance is not desirable, the vent exit must be shingles.
  • Page 16: Mobile Home Installation

    Conversion Kits The mobile home appliance is field convertible between Natural Gas (NG) and Propane (LP). To convert from one gas to another consult your Napoleon dealer/ distributor. FRAMING Note: In order to avoid the possibility of exposed insulation or...
  • Page 17: Nailing Tab Installation

    FIGURES 28a-c NAILING TAB INSTALLATION CORNER 1) Attach the nailing tabs to the corner POST posts using the 2 sheet metal screws supplied. Secure through the centre of NAILING the top and bottom slots in the nailing tab and then through the existing holes in the corner posts.
  • Page 18: Finishing

    FINISHING DOOR REMOVAL & INSTALLATION L36 LOUVRE INSTALLATION The upper louvres must be removed to allow the door to be Note: The protective wrap is best removed when the opened or closed. To access the lower door latch, open assembly is at room temperature but this can be improved the valve control door.
  • Page 19: Charcoal Embers

    PHAZER logs and glowing embers exclusive to Napoleon Fire- The top of the log should rest in the pocket on the rear log. places, provide a unique and realistic glowing effect that is different in every installation.
  • Page 20: Optional Blower Installation

    OPTIONAL BLOWER INSTALLATION INSTALLATION TO Attach BE DONE BY A c o n n e c t o r s QUALIFIED IN- from the black STALLER white must be electri- wires to the cally connected and t h e r m o d i s c grounded in accord- secure ance...
  • Page 21: Optional Fan Installation

    GD65 Fan Kit, shown above, which may be or- Unplug the power cord from the receptacle. Connect all dered from your Wolf Steel / Napoleon® dealer. wires as shown. With the thermostatic sensor option, the fan, when turned...
  • Page 22: Operation / Maintenance

    10 second total light-up period is satisfactory. If ignition takes remove the logs to expose both assemblies. longer, consult your Napoleon® dealer / distributor. 2. Keep the control compartment, logs, burner, air shutter 7. Check that the gasketing on the sides, top and bottom of opening and the area surrounding the logs clean by vacu- the door is not broken or missing.
  • Page 23: Adjustments

    ADJUSTMENTS PILOT BURNER ADJUSTMENT Closing the air shutter will cause a more yellow flame, but Adjust the pilot screw to provide properly sized flame. Turn can lead to carboning. Opening the air shutter will cause a in a clockwise direction to reduce the gas flow. more blue flame, but can cause flame lifting from the burner ports.
  • Page 24: Replacements

    Contact your dealer for questions concerning prices and When ordering replacement parts always give the follow- availability of replacement parts. Normally all parts can be ing information: ordered through your Napoleon dealer or distributor. 1. M & S ODEL ERIAL UMBER OF FIREPLACE 2.
  • Page 25 W415-0484 / C / 10.15.07...
  • Page 26: Trouble Shooting Guide

    TROUBLE SHOOTING GUIDE EFORE ATTEMPTING TO TROUBLESHOOT PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR OPENED. SYMPTOM PROBLEM TEST SOLUTION Main burner goes Pilot flame is not large - turn up pilot flame. out;...
  • Page 27 SYMPTOM PROBLEM TEST SOLUTION Pilot goes Gas piping is undersized. - turn on all gas appliances and see if pilot flame flutters, dimin- while standing; ishes or extinguishes, especially when main burner ignites. Monitor Main burner is in appliance supply working pressure. 'OFF' position.
  • Page 28 W415-0484 / C / 10.15.07...

This manual is also suitable for:

B36dfp

Table of Contents