General information about charging and discharging batteries
As a basic rule please be sure to observe the battery manufacturer's recommendations,
especially the information regarding maximum charge currents.
To ensure that the automatic Delta Peak circuit is able to work as efficiently as possible,
only properly balanced packs should be fast-charged. This means that new packs, and
packs which have not been used for a long time, should be discharged at regular intervals
and re-balanced by slow-charging at a low rate, typically C/10. To do this connect the bat-
tery and press the MODE button.
An occasional complete discharge process also helps to avoid and/or eliminate the

MEMORY EFFECT.

Notes
-
If the FAST CHARGING LED flashes, this indicates that the automatic charge termina-
tion circuit is active.
-
When 7-cell battery packs are being charged you may find that the charge current dec-
lines towards the end of the charge process.
-
Don't end the charge or discharge process simply by disconnecting the battery pack;
always stop the process by pressing the MODE button.
Mains PSU
-
If you use the Power Peak 7A mains PSU, Order No. 8415, the charger can also be ope-
rated from the 230 Volts mains supply, turning it into a universal 230 V AC and 12 V DC
charger.