Retest After Repair - Lincoln Electric POWER-ARC SVM103-C Service Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

F-35
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine's electrical characteristics.
OR
• If you repair or replace any electrical components.
Maximum Speed
Minimum Speed
Output Control
Field Volts
Maximum
Minimum
230 Volt Receptacle
Output
Open Circuit
Control
Volts
Maximum
255 - 267
1
Current Control Dial set at MAXIMUM or GENERATOR.
2
Output values of each receptacle can vary within the range shown
TROUBLESHOOTING & REPAIR

RETEST AFTER REPAIR

ENGINE OUTPUT
No Load RPM
WELDER/GENERATOR OUTPUT
Field Amps
43 - 49
4.8 - 5.8
AUXILIARY POWER RECEPTACLE OUTPUT
Load Volts
Load Amps
215 - 230
POWER-ARC 4000
3725
3675
1
Open Circuit
Volts
60 - 63
55 - 60
Open Circuit
Volts
18 - 20
127 - 133
Load RPM
3650
3400
Load Volts
Load Amps
12 - 25
120 - 125
14 - 27
75 - 85
1
115 Volt Receptacle
2
Load Volts
Load Amps
112 - 120
18 - 20
F-35

Hide quick links:

Advertisement