PL18M Blade Change Instructions Blade Handle Clamp Shroud Warning: this procedure is intended for a qualified equipment technician. It is not recommended for non-qualified personnel to service this unit. This unit contains an extremely sharp cutting blade which could cause severe personal injury if improperly handled.
Page 3
2. Remove shroud by taking out (3) 3mm Allen screws from shroud. See photo 2. Shroud cannot be removed before handle . 3. Remove plexi-glass clamp/guard by taking out (4) 3mm Allen screws from left and right side. A metal bracket under each side of the clamp may separate when this is performed.
Page 4
Clamp Removal--2 Screws at each end of clamp PHOTO 3 Removal Of Blade 1. Once clamp, shroud and handle are removed position blade handle so that both of the outer mounting screws are in sight. Remove each outer screw with 5mm Allen wrench.
Page 5
Martin Yale Industries, Inc. at 800-225-5644, or info@martinyale.com. Photo 1-Blade handle must be Do nut use hands to pull blade out. properly positioned to get access to Insert a small tool into blade hole the outer Allen screws.