After calling tour 1, the speed dome camera will move like this: 1
→ dwell six seconds → 10 → dwell six seconds → 15 → dwell six
seconds → 16 → dwell six seconds → 21 → dwell six seconds → 1
(repeat the tour)...

3.1.8. SET HOME POINT

Home point is a function that speed dome camera will automati-
cally move to a certain important preset which is set beforehand,
after a period of time without any operation made by operator. The
waiting time before entering into home status can be set from 1 to
255 seconds.
• Firstly, set a preset which you want be the home point.
• Set preset 121 to enter home point setting status.
• Set preset 122 to start home point.
• Set preset 123 to delete home point.

3.1.9. LEFT AND RIGHT LIMIT SCAN

User could set the left scan limit and right scan limit to make thermal
speed dome scan between them.
Call the camera to monitor (Enter IP address of camera then press
SHOT key).
Set preset 110 to set lift limit, then move the joystick to the position
where you want to set the right limit. Then set preset 111 to set right
limit. At last, move back 30 degree to avoid the speed dome camera
does not pan in the right direction.

3.1.10. RESTORE FACTORY DEFAULT

Call preset 150 would eliminate all the function which was set by
customer.

3.1.11. SPEED DOME COMMAND LIST

NOTE
Symbol "+" is stand for that the function is available.