Heat indicator light does not illuminate
Possible Causes
1. The heater switch is not turned on.
2. The machine power switch is not
turned on.
Reduced spray OR no spray
Possible cause
1. Bladder may be empty.
2. 2-in-1 tank may not be seated properly.
3. P ump may have lost prime.
4. The pump belt may be broken.
16
w w w . b i s s e l l . c a
A.
B.
Slots
Pump Belt
WARNING:
To reduce the risk of fire, electric
shock or injury, unplug from the
outlet before servicing.
Remedies
1. Turn on the heater switch located on
side of unit.
2. Both switches must be on
to activate the heat indicator light.
Remedies
1. Turn power switch off; Refill bladder
with clean hot tap water and formula.
2. Turn power switch off; remove tank
and reseat tanks.
3. Turn power switch off; after 1 minute
turn on and depress spray release trigger.
4. Turn power switch off and unplug
from the outlet. To check if a pump belt has
broken, you will need a flat head
screwdriver.
A. Insert the blade end into the slot of the
belt access door to release. Examine the
belt for breakage. You should be able to see
the pump belt looped around the motor shaft.
If it is broken or missing, please refer to
Replacement Parts on page 18.
A replacement belt may be ordered at
www.bissell.ca or by calling BISSELL
Consumer Services at 1-800-263-2535.
Complete installation instructions
will accompany the replacement belt.
B. When replacing belt access door be sure to
line up slots of belt access door with slots in
machine, slide door into place and snap shut.