BBV, SBV Series Natural Vent Gas Fireplaces

FIREPLACE LOCATION

Plan for the installation of your appliance. This includes de-
termining where the unit is to be installed, the vent configura-
tion to be used, framing and finishing details, and whether
any optional accessories (i.e. wall switch, or remote control)
are desired. Consult your local building code agency to en-
sure compliance with local codes, including permits and in-
spections.
The following factors should be taken into consideration:
Clearance to side-wall, ceiling, woodwork and windows.
Minimum clearances to combustibles must be main-
tained.
This fireplace may be installed along a wall, across a cor-
ner or use an exterior chase.
Location should be out of high traffic areas and away from furniture and draperies due to heat from
appliance.
Never obstruct the front opening of the fireplace.
Do not install in the vicinity where gasoline or other flammable liquids may be stored.
Vent pipe routing. Refer to Venting section found in this manual for allowable venting configura-
tions.
These units can be installed in a bedroom. Refer to the National Fuel Gas Code ANSI Z233.1/NFPA
54 - (current edition), the Uniform Mechanical Code - (current edition), and Local Building Codes for
specific installation requirements.
72" Minimum
Minimum 4"
From Both Side
Walls to Fire-
place
Opening
Figure 4 -

Clearances

8
8" Minimum
FP2018
clearances
PRE-INSTALLATION INFORMATION
CLEARANCES TO COMBUSTIBLES
Follow these instructions carefully to ensure
safe installation. Failure to follow instructions
exactly can create a fire hazard.
The appliance cannot be installed on a carpet,
tile or other combustible material other than
wood flooring. If installed on carpet or vinyl
flooring, the appliance shall be installed on a
metal, wood or noncombustible material panel
extending full width and depth of the appli-
ance.
12" Maximum
Depth
Side of Fireplace
Opening
Figure 4a -
Mantel Clearances
FP2582
FP2018
mantel side clearance
Combustible
Material Area
Wall
1"
1 "
2 "
2 "
45°
3"
4"
62D4037