Direct Vent Gas Fireplace for Mobile Homes
cleARANces to coMBustIBles
Follow these instructions carefully to ensure safe installation. Failure to follow
instructions exactly can create a fire hazard.
the appliance cannot be installed on a carpet, tile or other combustible material
other than wood flooring. If installed on carpet or vinyl flooring, the appliance
shall be installed on a metal, wood or noncombustible material panel extending
full width and depth of the appliance.
71" Minimum
Min. 4"
From Either
Side Wall
Figure 4 -
Clearances
MANtel cleARANces
Note: The combustible area above the facing must
not protrude more than 1/" from the facing. If it does,
it is considered a mantel and must meet the mantel
requirements listed in this manual.
8
11" Minimum
FP2248
mantel clearances
Wall
12"
8"
11"
7"
5"
12"
Min.
Top of Exhaust
Louvers
FP380
Side of Fire-
place Opening
Figure 5 -
Mantel Clearances
FP2380
mantel side clearance
cleARANces
Stud
Insulation
Board
6"
2"
3"
FP04a
side View
FP2204a
mantel clearances
Combustible
Material Area
Wall
1"
1 "
2 "
2 "
3"
4"
top View
Standoff
45°
54D4500