SOLUTION FILTER CLEANING

1.
Drain all the water from Solution tank as previously outlined.
2.
Move the machine to a fl at and smooth surface.
3.
Press the power switch (38) to the "O" position to turn off the machine.
4.
Turn off the draining ball valve (A, Figure 12) (located at the bottom of the machine, behind the wheels). Position B ball valve open, and
position C ball valve closed.
5.
Remove the transparent cap (D), and then take off the fi lter (E), and install them onto the fi lter box (F) after cleaning.
NOTE
The fi lter (E) must be accurately installed onto the position of the housing (G).
6.
Open the draining ball valve (A).

TROUBLESHOOTING

Breakdown
Machine not working
Vacuum motor not working
Little or no solution fl ow
Inadequate Vacuum
Squeegee leaving marks
7/2014
FIGURE 12
Probable Cause
The wiring not connected correctly or bad
wiring
Bad brush motor
Carbon brush worn out
The wiring not connected correctly or bad
wiring
Bad vacuum motor
Carbon brush worn out
Bad ball valve
Bad solution valve
Ball valve position in need of adjustment
Filter dirty
Recovery tank is full.
Drain hose and squeegee hose not properly
connected
Float fi lter blocked or inlet blocked
Squeegee dirty or squeegee blade worn and
damaged
Recovery tank lid not properly sealed, or the
seal / gasket for recovery tank damaged
Debris fragments under the squeegee blade
Squeegee blade worn, cracked or brittle.
Balance of squeegee not adjusted
INSTRUCTIONS FOR USE
Remedies
Check the wiring or contact Clarke
Distributor
Contact Clarke Distributor
Contact Clarke Distributor
Check the wiring or contact Clarke
Distributor
Contact Clarke Distributor
Contact Clarke Distributor
Contact Clarke Distributor
Contact Clarke Distributor
When ball valve is in horizontal
position, the amount of solution fl ow
is maximum
Clean the fi lter
Drain the recovery tank
Connect the drain hose and the
squeegee hose
Clean the fl oat fi lter, check the fl oat
ball
Clean and check the squeegee
Refi t on the lid properly, replace the
recovery tank seal
/ gasket
Remove the fragments
Replace the squeegee blade
Adjust the balance
56091131 - CA30 17E
ENGLISH - A