Datalogic DS6300 Reference Manual page 42

Datalogic laser bar code scanner reference manual
Hide thumbs Also See for DS6300:
Table of Contents

Advertisement

2
Figure 42 – DS6300-XXX-010 Master/Slave Lonworks Connection
The maximum current to be propagated to the slave readers through the
master is 2 A.
For this reason, it is suggested the use of a 24 V power supply allowing to
supply up to three readers (master + 2 slaves).
CAUTION
The following diagrams represent different network terminations using the BTK-6000
terminator. In each diagram the terminator is indicated by the
below shows its electrical circuit in details:
The diagram below represents the termination of a DS6300-XXX-010 working as master by
means of the BTK-6000 terminator.
28
Master
VS_I/O
4
5
REF_I/O
3
LON A
7
LON B
8
1
VS
AWG 16
9
GND
AWG 16
2
= male connector
= female connector
Figure 43 – BTK-6000 Electrical Circuit
Master
VS
9
VS_I/O
6
LON A
7
LON B
8
GND
2
REF_I/O
3
= male connector
= female connector
Figure 44 – DS6300-XXX-010 Master Termination
Slave
4
5
3
7
8
1
9
2
element, while the figure
BTK-6000 Female Side
9
6
7
T
8
2
3
DS6300